Evaluation of the Potential of a Ratiometric Fluorescence Sensor for Sensitively Recognizing 1-Hydroxypyrene in Real Urine Samples Based on a Stable Zn-MOF
Inorganic Chemistry · 2025
DOI: 10.1021/acs.inorgchem.4c05281 ↗Kurz gefasst
Fachartikel in der Zeitschrift Inorganic Chemistry, 2025. Verfasst von Shuting Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng 252059, P. R. China. Hauptthemen laut MEDLINE: Metal-Organic Frameworks, Fluorescent Dyes, Pyrenes, Zinc. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
In the work, a 3D Zn-based MOF, [CH3(NH2)2][Zn2(obdb)(OH)]·DMF (compound 1) has been formed successfully through the self-assembly of Zn(II) ion and organic linker H4obdb (4',4‴-oxybis[1,1'-biphenyl]-3,5-dicarboxylic acid, a high-symmetrical tetra-carboxylate ligand) under solvothermal conditions. In the structure of compound 1, Zn and the symmetry-generated ones constitute a tetra-nuclear cluster [Zn4(μ2-COO)8(μ3-OH)2], and then by the coordination of tetra-nuclear clusters and the organic linkers, a 3D stair-like framework containing a 1D rectangular channel with the porosity of 47.3% is generated. Interestingly, compound 1 is confirmed to possess striking air and pH stability. Noteworthily, the results of detecting studies certify that compound 1 can serve as a prospective ratiometric fluorescence sensor for selectively recognizing 1-hydroxypyrene (1-HP) among diverse urine components and a promising fluorescence probe for Asp from other 11 kinds of amino acids depended on "turn-off" effects decorated with high quenching efficiencies (97.5% for 1-HP and 94.3% for Asp) and outstanding sensitivity with Ksv values of 1.84 × 105 M-1 for 1-HP and 1.41 × 104 M-1 for Asp in a DMF-H2O binary system. Amazingly, the sensing capacities of compound 1 maintain similar levels in fresh human urine compared with those in the DMF-H2O binary system, giving the Ksv values of 5.79 × 104 M-1 for 1-HP and 1.72 × 104 M-1 for Asp.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng 252059, P. R. China.
- School of Materials Science and Engineering, National Institute for Advanced Materials, Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300350, China.
ORCID-Profile: Bo Zhang, Jiandong Pang, Yan Yang, Jun Li
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
Zitieren
APA
Xu, S., Liu, J., Zhang, B., Pang, J., Yang, Y., & Li, J. (2025). Evaluation of the Potential of a Ratiometric Fluorescence Sensor for Sensitively Recognizing 1-Hydroxypyrene in Real Urine Samples Based on a Stable Zn-MOF. Inorganic Chemistry. https://doi.org/10.1021/acs.inorgchem.4c05281
Vancouver
Xu S, Liu J, Zhang B, Pang J, Yang Y, Li J. Evaluation of the Potential of a Ratiometric Fluorescence Sensor for Sensitively Recognizing 1-Hydroxypyrene in Real Urine Samples Based on a Stable Zn-MOF. Inorganic Chemistry. 2025. doi:10.1021/acs.inorgchem.4c05281
BibTeX
@article{Xu2025,
author = {Xu, Shuting and Liu, Junxi and Zhang, Bo and Pang, Jiandong and Yang, Yan and Li, Jun},
title = {Evaluation of the Potential of a Ratiometric Fluorescence Sensor for Sensitively Recognizing 1-Hydroxypyrene in Real Urine Samples Based on a Stable Zn-MOF},
journal = {Inorganic Chemistry},
year = {2025},
doi = {10.1021/acs.inorgchem.4c05281}
}
EUVIMED