EUVIMEDEUVIMED entdecken
Crossref

Bridging Component Strategy in Phosphomolybdate-Based Sensors for Electrochemical Determination of Trace Cr(VI)

Jing-Yan He, Hao-Xue Bi, Yu-Qing Liu, Meng-Si Guo, Wen-Ting An, Yuan-Yuan Ma iD, Zhan-Gang Han iD

Inorganic Chemistry · 08.01.2024 · 63 (1) · 842-851

DOI: 10.1021/acs.inorgchem.3c03841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Inorganic Chemistry, online erschienen am 15.12.2023. Verfasst von Jing-Yan He und 6 weiteren Autor:innen. Beteiligte Einrichtung: Hebei Key Laboratory of Organic Functional Molecules, National Demonstration Center for Experimental Chemistry Education, Hebei Key Laboratory of Ino…. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Natural Science Foundation of Hebei Province, China Postdoctoral Science Foundation, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and sensitive electrochemical determination of trace carcinogenic Cr(VI) pollutants remains an urgent and important task, which requires the development of active sensing materials. Herein, four cases of reduced phosphomolybdates with formulas of the (H2bib)3[Zn(H2PO4)]2{Mn[P4Mo6O31H7]2}·6H2O (1), (H2bib)2[Na(H2O)]2[Mn(H2O)]2{Mn[P4Mo6O31H6]2}·5H2O (2), (H2bib)3[Mo2(μ2-O)2(H2O)4]2{Ni[P4Mo6O31H2]2}·4H2O (3), and (H2bib)2{Ni[P4Mo6O31H9]2}·9H2O (4) (bib = 4,4'-bis(1-imidazolyl)-biphenyl) were hydrothermally synthesized under the guidance of a bridging component strategy, which function as effective electrochemical sensors to detect trace Cr(VI). The difference of hybrids 1-4 is in the inorganic moiety, in which the reduced phosphomolybdates {M[P4MoV6O31]2} (M{P4Mo6}2) exhibited different arrangements bridged by different cationic components ({Zn(H2PO4)} subunit for 1, [Mn2(H2O)2]4+ dimer for 2, and [MoV2(μ2-O)2(H2O)4]6+ for 3). As a result, hybrids 1 and 3 display noticeable Cr(VI) detection activity with low detection limits of 14.3 nM (1.48 ppb) for 1 and 6.61 nM (0.69 ppb) for 3 and high sensitivities of 97.3 and 95.3 μA·mM-1, respectively, which are much beyond the World Health Organization's detection threshold (0.05 ppm) and superior to those of the contrast samples (inorganic Mn{P4Mo6}2 salt and hybrid 4), even the most reported noble-metal catalysts. This work supplies a prospective pathway to build effective electrochemical sensors based on phosphomolybdates for environmental pollutant treatment.

Autor:innen und Institutionen

  • Hebei Key Laboratory of Organic Functional Molecules, National Demonstration Center for Experimental Chemistry Education, Hebei Key Laboratory of Inorganic Nanomaterials, College of Chemistry and Materials Science, Hebe…

ORCID-Profile: Yuan-Yuan Ma, Zhan-Gang Han

Förderung

  • Natural Science Foundation of Hebei Province
  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Hebei Province

Zitieren

APA

He, J. Y., Bi, H. X., Liu, Y. Q., Guo, M. S., An, W. T., Ma, Y. Y., & Han, Z. G. (2024). Bridging Component Strategy in Phosphomolybdate-Based Sensors for Electrochemical Determination of Trace Cr(VI). Inorganic Chemistry, 63(1), 842-851. https://doi.org/10.1021/acs.inorgchem.3c03841

Vancouver

He JY, Bi HX, Liu YQ, Guo MS, An WT, Ma YY, et al. Bridging Component Strategy in Phosphomolybdate-Based Sensors for Electrochemical Determination of Trace Cr(VI). Inorganic Chemistry. 2024;63(1):842-851. doi:10.1021/acs.inorgchem.3c03841

BibTeX
@article{He2024,
  author = {He, Jing-Yan and Bi, Hao-Xue and Liu, Yu-Qing and Guo, Meng-Si and An, Wen-Ting and Ma, Yuan-Yuan and Han, Zhan-Gang},
  title = {Bridging Component Strategy in Phosphomolybdate-Based Sensors for Electrochemical Determination of Trace Cr(VI)},
  journal = {Inorganic Chemistry},
  year = {2024},
  volume = {63},
  number = {1},
  pages = {842--851},
  doi = {10.1021/acs.inorgchem.3c03841}
}