Development of a Wearable Device for Precise Assessment of Particle Deposition in the Human Respiratory System
Environmental Science & Technology · 18.08.2026 · 60 (32) · 22781-22790
DOI: 10.1021/acs.est.6c05543 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 03.08.2026. Verfasst von Xi-En Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Environmental Chemistry and Toxicology, Research Center for Eco-Environmental Sciences, Beijing100085, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Respiratory System. Die Arbeit nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Sciences, National Key Research and Development Program of China.
Abstract (Originalsprache)
The adverse respiratory health effects of particulate matter (PM) are well documented, yet real-world exposure and deposition within the human respiratory system remain poorly quantified. Here, we report a wearable device capable of simultaneously collecting PM from inhaled and exhaled breath to directly assess particle deposition under real-world conditions. Designed as a face mask, the device draws ambient air for inhalation while capturing exhaled aerosol, enabling direct comparison between inhaled and exhaled particles. Laboratory validation confirmed efficient collection of exhaled particles with minimal interference from ambient air. We deployed the device in subway environments, where 12 healthy volunteers participated in real-world exposure scenarios. Distinct differences in particle-size distributions between inhaled and exhaled breath were observed, indicating particle deposition and transformation within the respiratory tract. On average, ∼66% of inhaled PM is deposited in the respiratory system, with the highest deposition for particles smaller than 1.0 μm (PM1). Elemental analysis showed that metallic elements, including Fe, Cu, and Pb, dominated subway PM, and their deposition varied with individual characteristics such as lung function and exercise habits. These findings provide real-time evidence of PM deposition in humans and highlight the potential of wearable technologies for real-time assessment of air-pollution exposure and health risks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Environmental Chemistry and Toxicology, Research Center for Eco-Environmental Sciences, Beijing100085, China.
- School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou310024, China.
- School of Environment & Health, Jianghan University, Wuhan430056, China.
- University of Chinese Academy of Sciences, Beijing100190, China.
ORCID-Profile: Shaowei Yan, Qian Liu, Guibin Jiang
Förderung
- National Natural Science Foundation of China
- Chinese Academy of Sciences
- National Key Research and Development Program of China
Zitieren
APA
Zhang, X. E., Wang, D., Huang, C., Yan, S., Zhang, J., Liu, Q., & Jiang, G. (2026). Development of a Wearable Device for Precise Assessment of Particle Deposition in the Human Respiratory System. Environmental Science & Technology, 60(32), 22781-22790. https://doi.org/10.1021/acs.est.6c05543
Vancouver
Zhang XE, Wang D, Huang C, Yan S, Zhang J, Liu Q, et al. Development of a Wearable Device for Precise Assessment of Particle Deposition in the Human Respiratory System. Environmental Science & Technology. 2026;60(32):22781-22790. doi:10.1021/acs.est.6c05543
BibTeX
@article{Zhang2026,
author = {Zhang, Xi-En and Wang, Deliang and Huang, Cha and Yan, Shaowei and Zhang, Junpeng and Liu, Qian and Jiang, Guibin},
title = {Development of a Wearable Device for Precise Assessment of Particle Deposition in the Human Respiratory System},
journal = {Environmental Science & Technology},
year = {2026},
volume = {60},
number = {32},
pages = {22781--22790},
doi = {10.1021/acs.est.6c05543}
}
EUVIMED