IodoFinder: Machine Learning-Guided Recognition of Iodinated Chemicals in Nontargeted LC-MS/MS Analysis
Environmental Science & Technology · 11.03.2025 · 59 (9) · 4530-4539
DOI: 10.1021/acs.est.4c12698 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 27.02.2025. Verfasst von Tingting Zhao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, University of British Columbia, Vancouver Campus, 2036 Main Mall, Vancouver, British Columbia V6T 1Z1, C…. Hauptthemen laut MEDLINE: Machine Learning. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Genome British Columbia, Canada Foundation for Innovation, Canada Research Chairs.
Abstract (Originalsprache)
Iodinated disinfection byproducts (I-DBPs) pose significant health concerns due to their high toxicity. Current approaches to recognize unknown I-DBPs in mass spectrometry (MS) analysis rely on negative ionization mode, in which the characteristic I – fragment can be observed in tandem mass spectra (MS/MS). Still, many I-DBPs ionize exclusively in positive ionization mode, where the I – fragment is absent. To address this gap, this work developed a machine learning-based strategy to recognize iodinated compounds (I-compounds) from their MS/MS in both electrospray positive (ESI+) and negative ionization (ESI−) modes. Investigating over 6000 MS/MS spectra of 381 I-compounds, we first identified five characteristic I-containing neutral losses and one diagnostic I – fragment in ESI+ and ESI– modes, respectively. We then trained Random Forest models and integrated them into IodoFinder, a Python program, to streamline the recognition of I-compounds from raw LC-MS data. IodoFinder accurately recognized over 96% of the 161 I-compound standards in both ionization modes. In its application to DBP mixtures, IodoFinder discovered 19 I-DBPs with annotated structures and an additional 17 with assigned formulas, including 12 novel and 3 confirmed I-DBPs. We envision that IodoFinder will advance the identification of both known and unknown I-compounds in exposome studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Science, University of British Columbia, Vancouver Campus, 2036 Main Mall, Vancouver, British Columbia V6T 1Z1, Canada.
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta T6G 2G3, Canada.
ORCID-Profile: Xing-Fang Li, Tao Huan
Förderung
- Genome British Columbia
- Canada Foundation for Innovation
- Canada Research Chairs
- Genome Canada
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Zhao, T., Shen, Q., Li, X. F., & Huan, T. (2025). IodoFinder: Machine Learning-Guided Recognition of Iodinated Chemicals in Nontargeted LC-MS/MS Analysis. Environmental Science & Technology, 59(9), 4530-4539. https://doi.org/10.1021/acs.est.4c12698
Vancouver
Zhao T, Shen Q, Li XF, Huan T. IodoFinder: Machine Learning-Guided Recognition of Iodinated Chemicals in Nontargeted LC-MS/MS Analysis. Environmental Science & Technology. 2025;59(9):4530-4539. doi:10.1021/acs.est.4c12698
BibTeX
@article{Zhao2025,
author = {Zhao, Tingting and Shen, Qiming and Li, Xing-Fang and Huan, Tao},
title = {IodoFinder: Machine Learning-Guided Recognition of Iodinated Chemicals in Nontargeted LC-MS/MS Analysis},
journal = {Environmental Science & Technology},
year = {2025},
volume = {59},
number = {9},
pages = {4530--4539},
doi = {10.1021/acs.est.4c12698}
}
EUVIMED