Low-Cost PM 2.5 Sensor Performance Characteristics against Meteorological Influence in Sub-Saharan Africa: Evidence from the Air Sensor Evaluation and Training Facility for the West Africa Project
Environmental Science & Technology · 08.04.2025 · 59 (13) · 6623-6635
DOI: 10.1021/acs.est.4c09752 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 25.03.2025. Verfasst von James Nimo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental and Sustainable Engineering, State University of New York, Albany, New York 12203, United States. Hauptthemen laut MEDLINE: Particulate Matter, Environmental Monitoring. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 81 Literaturangaben. Gefördert von: Clean Air Fund.
Abstract (Originalsprache)
Fine particulate matter (PM 2.5 ) pollution represents a major environmental health risk in Africa. The use of low-cost sensors (LCS) for air quality monitoring for policy and civic engagement in sub-Saharan Africa (SSA) has become paramount, as access to traditional reference-grade instruments is still sparse. Yet, studies pertaining to sensor performance under SSA’s meteorological conditions and diverse emission sources are limited. Hence, we tested eight low-cost PM 2.5 sensors on the market from different manufacturers containing Plantower PMS, Alphasense OPC-N3, and AVO-Sensor sensors by collocating them with the federal equivalent method Teledyne T640 to ascertain data accuracy, reliability, and responsiveness during wet and dry periods. After 6 months of collocation, PM 2.5 concentrations from the LCS showed low intrasensor variability in both the wet and dry periods, but high intersensor variability with the Teledyne T640. A strong relationship existed between the LCS and Teledyne T640, with average coefficient of determination ( R 2 ) values of 0.7 (range: 05–0.9) and 0.8 (0.64–0.97) in the wet and dry periods, respectively. Larger errors were also associated with LCS data during the dry than the wet period, with the average mean absolute error and root mean squared error, respectively, 4.5 and 5.3 times higher in the dry period. Uncertainties with large errors were also observed with high PM 2.5 measured in the wet period, levels that were more common during the dry period typically characterized by long-range transport of PM 2.5 pollution. The results show that season significantly affects LCS performance and data quality and that care must be taken during deployment and data usage in SSA, with regular maintenance, particularly in the dry season. Strong collaborative efforts between governmental agencies, industries, and civil society are needed to come up with an effective framework for their application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Environmental and Sustainable Engineering, State University of New York, Albany, New York 12203, United States.
- The Air Sensor Evaluation and Training Facility for West Africa, Department of Physics, University of Ghana, Legon, LG 25 Accra, Ghana.
- Department of Physics, University of Ghana, Legon, LG 25 Accra, Ghana.
- Department of Environmental Health Sciences, University of Massachusetts, Amherst, Massachusetts 01003, United States.
- Ghana Environmental Protection Authority, Box M.326, Accra GA-107-1998, Ghana.
- Kigali Collaborative Research Centre, BP6150 Kigali, Rwanda.
ORCID-Profile: James Nimo, Albert A Presto
Förderung
- Clean Air Fund
Zitieren
APA
Nimo, J., Borketey, M. A., Appoh, E. K., Morrison, A. K., Ibrahim-Anyass, Y., Owusu Tawiah, A., Arku, R. E., Amoah, S., Tetteh, E. N., Brown, T., Presto, A. A., Subramanian, R., Westervelt, D. M., Giordano, M. R., & Hughes, A. F. (2025). Low-Cost PM 2.5 Sensor Performance Characteristics against Meteorological Influence in Sub-Saharan Africa: Evidence from the Air Sensor Evaluation and Training Facility for the West Africa Project. Environmental Science & Technology, 59(13), 6623-6635. https://doi.org/10.1021/acs.est.4c09752
Vancouver
Nimo J, Borketey MA, Appoh EK, Morrison AK, Ibrahim-Anyass Y, Owusu Tawiah A, et al. Low-Cost PM 2.5 Sensor Performance Characteristics against Meteorological Influence in Sub-Saharan Africa: Evidence from the Air Sensor Evaluation and Training Facility for the West Africa Project. Environmental Science & Technology. 2025;59(13):6623-6635. doi:10.1021/acs.est.4c09752
BibTeX
@article{Nimo2025,
author = {Nimo, James and Borketey, Mathias A and Appoh, Emmanuel K-E and Morrison, Abena Kyerewaa and Ibrahim-Anyass, Yussif and Owusu Tawiah, Audrey and Arku, Raphael E and Amoah, Selina and Tetteh, Esi Nerquaye and Brown, Tim and Presto, Albert A and Subramanian, R and Westervelt, Daniel M and Giordano, Michael R and Hughes, Allison Felix},
title = {Low-Cost PM 2.5 Sensor Performance Characteristics against Meteorological Influence in Sub-Saharan Africa: Evidence from the Air Sensor Evaluation and Training Facility for the West Africa Project},
journal = {Environmental Science & Technology},
year = {2025},
volume = {59},
number = {13},
pages = {6623--6635},
doi = {10.1021/acs.est.4c09752}
}
EUVIMED