MXene-Coated Ion-Selective Electrode Sensors for Highly Stable and Selective Lithium Dynamics Monitoring
Environmental Science & Technology · 16.01.2024 · 58 (2) · 1359-1368
DOI: 10.1021/acs.est.3c06235 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 11.12.2023. Verfasst von Yuankai Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States. Hauptthemen laut MEDLINE: Ion-Selective Electrodes, Lithium, Nitrites, Transition Elements. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Environmental Protection Agency, National Science Foundation, U.S. Department of Agriculture.
Abstract (Originalsprache)
Lithium holds immense significance in propelling sustainable energy and environmental systems forward. However, existing sensors used for lithium monitoring encounter issues concerning their selectivity and long-term durability. Addressing these challenges is crucial to ensure accurate and reliable lithium measurements during the lithium recovery processes. In response to these concerns, this study proposes a novel approach involving the use of an MXene composite membrane with incorporated poly(sodium 4-styrenesulfonate) (PSS) as an antibiofouling layer on the Li+ ion selective electrode (ISE) sensors. The resulting MXene-PSS Li+ ISE sensor demonstrates exceptional electrochemical performance, showcasing a superior slope (59.42 mV/dec), lower detection limit (10-7.2 M), quicker response time (∼10 s), higher selectivity to Na+ (-2.37) and K+ (-2.54), and reduced impedance (106.9 kΩ) when compared to conventional Li+ ISE sensors. These improvements are attributed to the unique electronic conductivity and layered structure of the MXene-PSS nanosheet coating layer. In addition, the study exhibits the long-term accuracy and durability of the MXene-PSS Li+ ISE sensor by subjecting it to real wastewater testing for 14 days, resulting in sensor reading errors of less than 10% when compared to laboratory validation results. This research highlights the great potential of MXene nanosheet coatings in advancing sensor technology, particularly in challenging applications, such as detecting emerging contaminants and developing implantable biosensors. The findings offer promising prospects for future advancements in sensor technology, particularly in the context of sustainable energy and environmental monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States.
ORCID-Profile: Su Liu, Yongsheng Chen
Förderung
- U.S. Environmental Protection Agency
- National Science Foundation
- U.S. Department of Agriculture
Zitieren
APA
Huang, Y., Afolabi, M. A., Gan, L., Liu, S., & Chen, Y. (2024). MXene-Coated Ion-Selective Electrode Sensors for Highly Stable and Selective Lithium Dynamics Monitoring. Environmental Science & Technology, 58(2), 1359-1368. https://doi.org/10.1021/acs.est.3c06235
Vancouver
Huang Y, Afolabi MA, Gan L, Liu S, Chen Y. MXene-Coated Ion-Selective Electrode Sensors for Highly Stable and Selective Lithium Dynamics Monitoring. Environmental Science & Technology. 2024;58(2):1359-1368. doi:10.1021/acs.est.3c06235
BibTeX
@article{Huang2024,
author = {Huang, Yuankai and Afolabi, Moyosore A and Gan, Lan and Liu, Su and Chen, Yongsheng},
title = {MXene-Coated Ion-Selective Electrode Sensors for Highly Stable and Selective Lithium Dynamics Monitoring},
journal = {Environmental Science & Technology},
year = {2024},
volume = {58},
number = {2},
pages = {1359--1368},
doi = {10.1021/acs.est.3c06235}
}
EUVIMED