EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Microplate-Based Cell Viability Assay as a Cost-Effective Alternative to Flow Cytometry for Microalgae Analysis

Diyuan Wang iD, Francis L de Los Reyes iD, Joel J Ducoste iD

Environmental Science & Technology · 19.12.2023 · 57 (50) · 21200-21211

DOI: 10.1021/acs.est.3c05675 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Environmental Science & Technology, online erschienen am 04.12.2023. Verfasst von Diyuan Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States. Hauptthemen laut MEDLINE: Fluorescent Dyes, Microalgae. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cell viability is a critical indicator for assessing culture quality in microalgae cultivation for biorefinery and bioremediation. Fluorescent dyes that distinguish viable from nonviable cells can enable viability quantification based on the percentage of live cells. However, fluorescence analysis using the typical flow cytometry method is costly and impractical for industrial applications. To address this, we developed new microplate assays utilizing fluorescein diacetate as a live cell stain and erythrosine B as a dead cell stain. These assays provide a low-cost, simple, and reliable method of assessing cell viability. The proposed microplate assays were successfully applied to monitor the viability of the microalgae Dunaliella viridis under carbon and nitrogen limitation stresses and demonstrated good agreement with flow cytometry measurements. We conducted a systematic investigation of the effects of dye concentration, incubation time, and background fluorescence on the microplate assays' performance. Further, we provide a comprehensive review of commonly used fluorescent dyes for microalgae staining, discuss strategies to enhance assay performance, and offer recommendations for dye selection and protocol development. This study presents a comprehensive new method for microplate-based viability analysis, providing valuable insights for future microalgae viability assessments and applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesMicroalgaeFlow CytometryCell SurvivalCost-Benefit Analysis

Stichwörter der Autor:innen

Dunaliella viridiscell viabilityerythrosine Bfluorescein diacetate (FDA)fluorescent dyemicroalgaemicroplate reader

Substanzen

Fluorescent Dyes

Autor:innen und Institutionen

  • Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States.

ORCID-Profile: Diyuan Wang, Francis L de Los Reyes, Joel J Ducoste

Zitieren

APA

Wang, D., de Los Reyes, F. L., & Ducoste, J. J. (2023). Microplate-Based Cell Viability Assay as a Cost-Effective Alternative to Flow Cytometry for Microalgae Analysis. Environmental Science & Technology, 57(50), 21200-21211. https://doi.org/10.1021/acs.est.3c05675

Vancouver

Wang D, de Los Reyes FL, Ducoste JJ. Microplate-Based Cell Viability Assay as a Cost-Effective Alternative to Flow Cytometry for Microalgae Analysis. Environmental Science & Technology. 2023;57(50):21200-21211. doi:10.1021/acs.est.3c05675

BibTeX
@article{Wang2023,
  author = {Wang, Diyuan and de Los Reyes, Francis L and Ducoste, Joel J},
  title = {Microplate-Based Cell Viability Assay as a Cost-Effective Alternative to Flow Cytometry for Microalgae Analysis},
  journal = {Environmental Science & Technology},
  year = {2023},
  volume = {57},
  number = {50},
  pages = {21200--21211},
  doi = {10.1021/acs.est.3c05675}
}
Kostenlos starten →