EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes

Chih-Wei Liu iD, Jiahao Feng iD, Jingya Peng iD, Haoduo Zhao iD, Xueying Wang, B Bhaskar Gollapudi, Abby A Li, James S Bus, Christopher Kirman, Kun Lu iD

Chemical Research in Toxicology · 15.06.2026 · 39 (6) · 1084-1087

DOI: 10.1021/acs.chemrestox.6c00200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemical Research in Toxicology, online erschienen am 23.05.2026. Verfasst von Chih-Wei Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Sciences and Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States. Hauptthemen laut MEDLINE: Valine, Hemoglobins, Ethylene Oxide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIEHS NIH HHS, North Carolina State University, American Chemistry Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ethylene oxide (EtO) assessment relies on detecting the hemoglobin adduct N-(2-hydroxyethyl)-l-valine (HE-V). However, current methods require large blood volumes, limiting small-animal exposure studies and reliable detection of endogenous background levels of HE-V. We optimized a highly sensitive analytical workflow including hemoglobin extraction from microliter-scale blood samples, HE-V purification, and targeted LC-MS/MS quantitative analysis. This workflow reliably quantifies endogenous HE-V levels of unexposed mice from only 50 μg of purified hemoglobin (10 μL of blood) and is demonstrated to detect significant HE-V increases at EtO exposures as low as 0.05 ppm. Our platform enables practical EtO biomonitoring in volume-constrained experimental and environmental settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ValineHemoglobinsEthylene OxideAnimalsTandem Mass SpectrometryMiceLiquid Chromatography-Mass SpectrometryChromatography, Liquid

Substanzen

ValineHemoglobinsEthylene Oxide2-hydroxyethylvaline

Autor:innen und Institutionen

  • Department of Environmental Sciences and Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
  • Toxicology Consultant, Midland, Michigan 48640, United States.
  • Exponent, Inc. Health Sciences, Menlo Park, California 94025, United States.
  • SciPinion, Bozeman, Montana 59715, United States.

ORCID-Profile: Chih-Wei Liu, Jiahao Feng, Jingya Peng, Haoduo Zhao, Kun Lu

Förderung

  • NIEHS NIH HHS
  • North Carolina State University
  • American Chemistry Council

Zitieren

APA

Liu, C. W., Feng, J., Peng, J., Zhao, H., Wang, X., Gollapudi, B. B., Li, A. A., Bus, J. S., Kirman, C., & Lu, K. (2026). Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes. Chemical Research in Toxicology, 39(6), 1084-1087. https://doi.org/10.1021/acs.chemrestox.6c00200

Vancouver

Liu CW, Feng J, Peng J, Zhao H, Wang X, Gollapudi BB, et al. Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes. Chemical Research in Toxicology. 2026;39(6):1084-1087. doi:10.1021/acs.chemrestox.6c00200

BibTeX
@article{Liu2026,
  author = {Liu, Chih-Wei and Feng, Jiahao and Peng, Jingya and Zhao, Haoduo and Wang, Xueying and Gollapudi, B Bhaskar and Li, Abby A and Bus, James S and Kirman, Christopher and Lu, Kun},
  title = {Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes},
  journal = {Chemical Research in Toxicology},
  year = {2026},
  volume = {39},
  number = {6},
  pages = {1084--1087},
  doi = {10.1021/acs.chemrestox.6c00200}
}
Kostenlos starten →