EUVIMEDEUVIMED entdecken
Open Access

Deploying Validated Mass Spectrometry for Frontline Detection and Treatment of Human Poisoning by Long-Acting Anticoagulant Rodenticides

Richard B van Breemen iD, Bianca Flores iD, Israel Rubinstein, Douglas L Feinstein

Chemical Research in Toxicology · 18.11.2024 · 37 (11) · 1769-1775

DOI: 10.1021/acs.chemrestox.4c00344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemical Research in Toxicology, online erschienen am 29.10.2024. Verfasst von Richard B van Breemen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Sciences, Linus Pauling Institute and College of Pharmacy, Oregon State University, Corvallis, Oregon 97331, United Stat…. Hauptthemen laut MEDLINE: Anticoagulants, Rodenticides. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: BLRD VA, NIEHS NIH HHS, NCCIH NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Derived from the same natural anticoagulant as warfarin (dicoumarol), long-acting anticoagulant rodenticides (LAARs) or superwarfarins have much longer half-lives in human blood than warfarin (weeks instead of hours) and are more potent inhibitors of the same enzyme, vitamin K epoxide reductase component 1. While used effectively worldwide as rodenticides, LAARs can elicit severe, protracted, life-threatening coagulopathy in humans at blood concentrations >10 ng/mL leading to numerous accidental and intentional poisonings annually. To facilitate timely identification and quantitative analysis of LAARs in patients presenting unexplained severe, protracted, life-threatening coagulopathy, several analytical methods have been developed, all of which are based on electrospray liquid chromatography-mass spectrometry (LC-MS). In this perspective, we evaluated and compared these LC-MS methods in terms of validation, simultaneous detection of multiple LAARs, measurement of individual stereoisomers, and clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnticoagulantsRodenticidesHumansChromatography, LiquidMass Spectrometry

Substanzen

AnticoagulantsRodenticides

Autor:innen und Institutionen

  • Department of Pharmaceutical Sciences, Linus Pauling Institute and College of Pharmacy, Oregon State University, Corvallis, Oregon 97331, United States.
  • Jesse Brown VA Medical Center and Department of Medicine, University of Illinois College of Medicine in Chicago, Chicago, Illinois 60612, United States.
  • Jesse Brown VA Medical Center and Department of Anesthesiology, University of Illinois College of Medicine in Chicago, Chicago, Illinois 60612, United States.

ORCID-Profile: Richard B van Breemen, Bianca Flores

Förderung

  • BLRD VA
  • NIEHS NIH HHS
  • NCCIH NIH HHS
  • NINDS NIH HHS
  • National Institute of Neurological Disorders and Stroke
  • U.S. Department of Veterans Affairs
  • National Center for Complementary and Integrative Health

Zitieren

APA

van Breemen, R. B., Flores, B., Rubinstein, I., & Feinstein, D. L. (2024). Deploying Validated Mass Spectrometry for Frontline Detection and Treatment of Human Poisoning by Long-Acting Anticoagulant Rodenticides. Chemical Research in Toxicology, 37(11), 1769-1775. https://doi.org/10.1021/acs.chemrestox.4c00344

Vancouver

van Breemen RB, Flores B, Rubinstein I, Feinstein DL. Deploying Validated Mass Spectrometry for Frontline Detection and Treatment of Human Poisoning by Long-Acting Anticoagulant Rodenticides. Chemical Research in Toxicology. 2024;37(11):1769-1775. doi:10.1021/acs.chemrestox.4c00344

BibTeX
@article{vanBreemen2024,
  author = {van Breemen, Richard B and Flores, Bianca and Rubinstein, Israel and Feinstein, Douglas L},
  title = {Deploying Validated Mass Spectrometry for Frontline Detection and Treatment of Human Poisoning by Long-Acting Anticoagulant Rodenticides},
  journal = {Chemical Research in Toxicology},
  year = {2024},
  volume = {37},
  number = {11},
  pages = {1769--1775},
  doi = {10.1021/acs.chemrestox.4c00344}
}
Kostenlos starten →