EUVIMEDEUVIMED entdecken
Crossref

A Phenanthrenequinone-Based Ratiometric Fluorescent Probe for Rapid Detection of Peroxynitrite with Imaging in Osteoblast Precursor Cells

Anirban Karak, Dipanjan Banik, Rajdeep Ganguly iD, Shilpita Banerjee, Pintu Ghosh, Anwesha Maiti, Debasish Mandal iD, Ajit Kumar Mahapatra iD

Chemical Research in Toxicology · 2024

DOI: 10.1021/acs.chemrestox.4c00023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemical Research in Toxicology, 2024. Verfasst von Anirban Karak und 7 weiteren Autor:innen. Beteiligte Einrichtung: Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Shibpur,Ho…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Peroxynitrous Acid, Osteoblasts, Phenanthrenes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Indian Institute of Engineering Science and Technology, Shibpur, Science and Engineering Research Board.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the current situation, peroxynitrite (ONOO-) is drawing the increasing attention of researchers for its pivotal role in diverse pathological and physiological processes on grounds of robust oxidation and nitrification. Herein, we have successfully designed and synthesized a phenanthrenequinone benzyl borate-based chemosensor for fast and selective detection of ONOO-. The probe PTDP itself had an orange fluorescence, which was changed to strong blue fluorescence upon the addition of ONOO-, indicating the ratiometric response of the probe. This is so because of the cleavage of the benzyl boronate-protecting group of PTDP upon the addition of ONOO- with simultaneous releasing of pyridinyl-based chemosensor PPI. The PTDP showed outstanding performance in the various photophysical studies such as good selectivity, excellent sensitivity with a very low detection limit of 2.74 nM, and a very fast response time (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesPeroxynitrous AcidOsteoblastsPhenanthrenesMolecular StructureOptical ImagingLimit of DetectionAnimalsHumansSpectrometry, Fluorescence

Substanzen

Fluorescent DyesPeroxynitrous AcidPhenanthrenes

Autor:innen und Institutionen

  • Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Shibpur,Howrah 711 103, India.
  • Centre for Healthcare Science, Indian Institute of Engineering Science and Technology, Shibpur,Howrah 711103, India.
  • School of Chemistry and Biochemistry, Thapar Institute of Engineering and Technology, Patiala ,Punjab 147004, India.

ORCID-Profile: Rajdeep Ganguly, Debasish Mandal, Ajit Kumar Mahapatra

Förderung

  • Indian Institute of Engineering Science and Technology, Shibpur
  • Science and Engineering Research Board

Zitieren

APA

Karak, A., Banik, D., Ganguly, R., Banerjee, S., Ghosh, P., Maiti, A., Mandal, D., & Mahapatra, A. K. (2024). A Phenanthrenequinone-Based Ratiometric Fluorescent Probe for Rapid Detection of Peroxynitrite with Imaging in Osteoblast Precursor Cells. Chemical Research in Toxicology. https://doi.org/10.1021/acs.chemrestox.4c00023

Vancouver

Karak A, Banik D, Ganguly R, Banerjee S, Ghosh P, Maiti A, et al. A Phenanthrenequinone-Based Ratiometric Fluorescent Probe for Rapid Detection of Peroxynitrite with Imaging in Osteoblast Precursor Cells. Chemical Research in Toxicology. 2024. doi:10.1021/acs.chemrestox.4c00023

BibTeX
@article{Karak2024,
  author = {Karak, Anirban and Banik, Dipanjan and Ganguly, Rajdeep and Banerjee, Shilpita and Ghosh, Pintu and Maiti, Anwesha and Mandal, Debasish and Mahapatra, Ajit Kumar},
  title = {A Phenanthrenequinone-Based Ratiometric Fluorescent Probe for Rapid Detection of Peroxynitrite with Imaging in Osteoblast Precursor Cells},
  journal = {Chemical Research in Toxicology},
  year = {2024},
  doi = {10.1021/acs.chemrestox.4c00023}
}
Kostenlos starten →