EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Solvent Emissions Prediction from Laboratory Fume Hoods: A Preliminary Study

Raffaele Emanuele Russo, Giacomo Seccacini, Paolo Cognigni, Martina Fattobene, Silvia Zamponi, Paolo Conti, Marco Ortelli, Mario Berrettoni

ACS Chemical Health & Safety · 26.01.2026 · 33 (1) · 138-146

DOI: 10.1021/acs.chas.5c00179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 15.01.2026. Verfasst von Raffaele Emanuele Russo und 7 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The correct use and performance assessment of chemical fume hoods are essential to minimize operator exposure to hazardous volatile compounds. In this study, a chemometric strategy was developed to predict solvent emissions based on molecular and physicochemical descriptors. A small but representative set of solvents (ethanol, diethyl ether, isopropanol, n-hexane, and acetone) was selected according to safety profiles and structural diversity. Controlled evaporation tests were carried out using a dynamic containment setup inspired by the EN 14175 outer plane methodology. Emissions were experimentally quantified under two standardized conditions. Initially, univariate regression models were developed using Ordinary Least Squares, with vapor pressure and boiling point as single predictors. Partial Least Squares regression was therefore applied to check ten chemical–physical molecular descriptors; variable selection reduced the number to the previous two. The reduced model improves prediction accuracy under both experimental conditions, reducing the error in prediction from 4.30 to 1.48 for the first setting and from 5.25 to 3.67 for the second setting. These results demonstrate that solvent emissions from laboratory fume hoods can be reliably predicted using chemometric models based on molecular descriptors. The proposed approach offers a valuable tool for emission assessment, informed solvent selection, and chemical risk management in laboratory environments.

Zitieren

APA

Russo, R. E., Seccacini, G., Cognigni, P., Fattobene, M., Zamponi, S., Conti, P., Ortelli, M., & Berrettoni, M. (2026). Solvent Emissions Prediction from Laboratory Fume Hoods: A Preliminary Study. ACS Chemical Health & Safety, 33(1), 138-146. https://doi.org/10.1021/acs.chas.5c00179

Vancouver

Russo RE, Seccacini G, Cognigni P, Fattobene M, Zamponi S, Conti P, et al. Solvent Emissions Prediction from Laboratory Fume Hoods: A Preliminary Study. ACS Chemical Health & Safety. 2026;33(1):138-146. doi:10.1021/acs.chas.5c00179

BibTeX
@article{Russo2026,
  author = {Russo, Raffaele Emanuele and Seccacini, Giacomo and Cognigni, Paolo and Fattobene, Martina and Zamponi, Silvia and Conti, Paolo and Ortelli, Marco and Berrettoni, Mario},
  title = {Solvent Emissions Prediction from Laboratory Fume Hoods: A Preliminary Study},
  journal = {ACS Chemical Health & Safety},
  year = {2026},
  volume = {33},
  number = {1},
  pages = {138--146},
  doi = {10.1021/acs.chas.5c00179}
}
Kostenlos starten →