Chemical Hazard Assessment of Asymmetric Vanadium Flow Battery Electrolytes in Failure Mode
ACS Chemical Health & Safety · 22.09.2025 · 32 (5) · 637-648
DOI: 10.1021/acs.chas.5c00098 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 13.08.2025. Verfasst von Kourosh Khaje und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 88 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Emerging battery technologies are transforming the landscape of energy storage. Within this domain, flow batteries are increasingly seen as critical enablers for the integration and deployment of renewable energy systems. Nevertheless, the electrolytes utilized in these systems present potential risks to both human health and environmental safety. Over the past five decades, vanadium–vanadium flow batteries have become a commercially viable solution; however, several distinct electrolyte compositions have been proposed for asymmetric vanadium flow batteries (V-X FB: X = Ce, Br, Fe, Mn, Zn, H2, O2), each driven by unique technical and commercial motivations. This study aims to evaluate their risks, prioritize further research investments, and identify gaps in current efforts to advance safer and more sustainable energy storage technologies. This research builds on our prior work, entitled Chemical Hazard Assessment of Vanadium–Vanadium Flow Battery Electrolytes in Failure Mode, [ Khaje, K.; et al.ACS Chem. Health Saf.2025, 32, 449–460]. But shifts the focus to asymmetric vanadium flow batteries that are at a lower technology readiness level and are earlier in the commercialization pathway. Overcharging of batteries has been identified as one of the primary potential failure modes, directly leading to electrolyte degradation. This condition poses significant hazards due to the potential generation of toxic gases. Depending on the electrolyte composition, overcharging may result in the release of gases, such as Cl2, Br2, SO2, H2S, PH3, NO2, CO2, NH3, or HCN, each carrying immediate risks to human health. This study shows that electrolytes containing bromide, chloride, and cyanide ions are particularly concerning, as they present the most severe toxicity hazards during failure modes. Future experimental work is needed to evaluate conditions under which gases are produced by these flow batteries under both normal and severe overcharging conditions and to quantify the associated hazards. This will provide critical insights for improving battery safety and guiding future research and development in energy storage technologies.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Khaje, K., Fuladpanjeh-Hojaghan, B., Gailer, J., Birss, V., & Roberts, E. P. L. (2025). Chemical Hazard Assessment of Asymmetric Vanadium Flow Battery Electrolytes in Failure Mode. ACS Chemical Health & Safety, 32(5), 637-648. https://doi.org/10.1021/acs.chas.5c00098
Vancouver
Khaje K, Fuladpanjeh-Hojaghan B, Gailer J, Birss V, Roberts EPL. Chemical Hazard Assessment of Asymmetric Vanadium Flow Battery Electrolytes in Failure Mode. ACS Chemical Health & Safety. 2025;32(5):637-648. doi:10.1021/acs.chas.5c00098
BibTeX
@article{Khaje2025,
author = {Khaje, Kourosh and Fuladpanjeh-Hojaghan, Behzad and Gailer, Jürgen and Birss, Viola and Roberts, Edward P. L.},
title = {Chemical Hazard Assessment of Asymmetric Vanadium Flow Battery Electrolytes in Failure Mode},
journal = {ACS Chemical Health & Safety},
year = {2025},
volume = {32},
number = {5},
pages = {637--648},
doi = {10.1021/acs.chas.5c00098}
}