EUVIMEDEUVIMED entdecken
Crossref

Quantitative Risk-Informed Sensor Placement Optimization for Chemical Leak Detection in a Complex Laboratory Layout Using the CFD-ANN Approach

Xu Zhang, Michelle Xin Yi Ng, Kai Xiang Yu, Joon Yoon Ten, Khang Wei Tan, Weng Hoong Lam, Peng Chee Tan, Thomas Shean Yaw Choong, Parthiban Siwayanan, Kek Seong Kim, Zhen Hong Ban

ACS Chemical Health & Safety · 24.11.2025 · 32 (6) · 716-736

DOI: 10.1021/acs.chas.5c00089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 04.11.2025. Verfasst von Xu Zhang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Xiamen University, Hengyuan International Sdn. Bhd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid and accurate localization of hazardous chemical leak sources is critical for mitigating environmental damage, protecting public health, and ensuring an effective emergency response. However, the conventional source localization method can be slow and inefficient. To address this challenge, this research proposes and develops a novel integrated system leveraging computational fluid dynamics (CFD), sensor network optimization, and artificial neural networks (ANN) for the precise localization of chemical sources, focusing on ethanol leaks within a laboratory environment. The dispersion of ethanol gas was simulated using CFD, and the simulation data were used for sensor optimization. The sensor system, consisting of 10 sensors at vital locations, is the foundation for the development of the ANN-based source localization method. The environmental factors related to gas dispersion considered were wind speed, wind direction, and temperature, as well as the presence of exhaust and air supply systems. A total of 4 leakage points were studied. The concentration data measured by the sensor system were used to train the ANN to identify the most probable location of the ethanol leak. The model achieved a validation percentage of 87.5% and an average error of 0.0001% in determining the ethanol leak location of four release points in the study area. The findings demonstrate that this combined CFD-ML approach offers a powerful and efficient tool for improving emergency response protocols, enhancing safety measures, and mitigating potential financial losses during chemical incidents.

Förderung

  • Xiamen University
  • Hengyuan International Sdn. Bhd.

Zitieren

APA

Zhang, X., Ng, M. X. Y., Yu, K. X., Ten, J. Y., Tan, K. W., Lam, W. H., Tan, P. C., Choong, T. S. Y., Siwayanan, P., Kim, K. S., & Ban, Z. H. (2025). Quantitative Risk-Informed Sensor Placement Optimization for Chemical Leak Detection in a Complex Laboratory Layout Using the CFD-ANN Approach. ACS Chemical Health & Safety, 32(6), 716-736. https://doi.org/10.1021/acs.chas.5c00089

Vancouver

Zhang X, Ng MXY, Yu KX, Ten JY, Tan KW, Lam WH, et al. Quantitative Risk-Informed Sensor Placement Optimization for Chemical Leak Detection in a Complex Laboratory Layout Using the CFD-ANN Approach. ACS Chemical Health & Safety. 2025;32(6):716-736. doi:10.1021/acs.chas.5c00089

BibTeX
@article{Zhang2025,
  author = {Zhang, Xu and Ng, Michelle Xin Yi and Yu, Kai Xiang and Ten, Joon Yoon and Tan, Khang Wei and Lam, Weng Hoong and Tan, Peng Chee and Choong, Thomas Shean Yaw and Siwayanan, Parthiban and Kim, Kek Seong and Ban, Zhen Hong},
  title = {Quantitative Risk-Informed Sensor Placement Optimization for Chemical Leak Detection in a Complex Laboratory Layout Using the CFD-ANN Approach},
  journal = {ACS Chemical Health & Safety},
  year = {2025},
  volume = {32},
  number = {6},
  pages = {716--736},
  doi = {10.1021/acs.chas.5c00089}
}
Kostenlos starten →