Multisource Leakage-Monitoring Device for Gas Transmission Pipeline in Chemical Park and Experimental Research
ACS Chemical Health & Safety · 28.07.2025 · 32 (4) · 488-503
DOI: 10.1021/acs.chas.5c00061 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 08.07.2025. Verfasst von Jixin Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: University Student Research and Training Program.
Abstract (Originalsprache)
In this study, an experimental platform for the safe operation and leakage monitoring of pipelines in chemical parks was developed, integrating an acoustic emission system for real-time detection. The reliability of the platform was verified through pressure tightness testing, data reproducibility verification, acoustic emission experiments, and CFD simulations. Static and dynamic leakage experiments demonstrated that the effect of initial pressure on leakage is significantly enhanced when the total leakage pore diameter exceeds 4 mm (pore diameter ratio of 0.05). Additionally, the impact of multihole leakage increases substantially when the diameter of a single hole reaches 15 mm (pore diameter ratio of 0.19). The study revealed a positive correlation between the initial pressure and the rate of pressure change, an exponential relationship between leakage hole diameter and pressure change rate, and a threshold effect of leakage hole diameter on the final pipeline pressure. These findings provide empirical support for the development of pipeline safety management strategies and hold significant practical value in enhancing pipeline safety and emergency response capabilities. The platform enables effective monitoring of leakage dynamics through multidimensional validation, offering a scientific basis for pipeline risk prevention and control in chemical parks.
Förderung
- University Student Research and Training Program
Zitieren
APA
Zhang, J., Li, Z., Xia, Y., Wang, L., Liu, B., & You, Q. (2025). Multisource Leakage-Monitoring Device for Gas Transmission Pipeline in Chemical Park and Experimental Research. ACS Chemical Health & Safety, 32(4), 488-503. https://doi.org/10.1021/acs.chas.5c00061
Vancouver
Zhang J, Li Z, Xia Y, Wang L, Liu B, You Q. Multisource Leakage-Monitoring Device for Gas Transmission Pipeline in Chemical Park and Experimental Research. ACS Chemical Health & Safety. 2025;32(4):488-503. doi:10.1021/acs.chas.5c00061
BibTeX
@article{Zhang2025,
author = {Zhang, Jixin and Li, Zhonghao and Xia, Yimeng and Wang, Lan and Liu, Bingjun and You, Qiuju},
title = {Multisource Leakage-Monitoring Device for Gas Transmission Pipeline in Chemical Park and Experimental Research},
journal = {ACS Chemical Health & Safety},
year = {2025},
volume = {32},
number = {4},
pages = {488--503},
doi = {10.1021/acs.chas.5c00061}
}