EUVIMEDEUVIMED entdecken
Crossref

Comparison of Measured Radiation Exposure and Dose Rates with Analytical and Computational Methods

Syed F. Naeem, Christopher R. Fitzgerald, Brian Champine, Tony Sorensen

ACS Chemical Health & Safety · 26.05.2025 · 32 (3) · 259-265

DOI: 10.1021/acs.chas.4c00115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 26.03.2025. Verfasst von Syed F. Naeem und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Lawrence Livermore National Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Proper selection and utilization of survey instruments are important to fulfilling radiation survey needs. Ion chambers are typically used to survey β and γ-ray radiation, whereas REM balls containing helium-3 detectors are used to survey neutrons. While analytical calculations provide good estimates of radiation doses, it becomes challenging to estimate doses in the presence of shielding material(s) under complex geometries. γ doses are underestimated without accounting for buildup in the shielding equation. Commercially available software such as MicroShield can be used to calculate final γ radiation exposure, which relies on mathematical techniques to account for the radiation buildup in complex geometries. However, MicroShield is limited to assessing γ exposure and doses. Both γ and neutron radiation doses can be modeled using Monte Carlo particle transport methods in the computer code MCNP. Neutron and γ radiation doses from various spontaneous fission sources can also be modeled in the MCNP. However, this is dependent upon implementing proper fission models in the MCNP to calculate neutron and γ radiation doses. MicroShield in the default configuration cannot calculate γ radiation doses from spontaneous fission sources. However, the γ radiation dose from a spontaneous fission source can be correctly calculated in MicroShield if a γ spectrum is provided. MicroShield, MCNP, and analytical calculations show good agreement with measurements for γ sources used in the paper. On the other hand, MCNP and analytical calculations show good agreement with measurements for the spontaneous fission source used in the paper.

Förderung

  • Lawrence Livermore National Laboratory

Zitieren

APA

Naeem, S. F., Fitzgerald, C. R., Champine, B., & Sorensen, T. (2025). Comparison of Measured Radiation Exposure and Dose Rates with Analytical and Computational Methods. ACS Chemical Health & Safety, 32(3), 259-265. https://doi.org/10.1021/acs.chas.4c00115

Vancouver

Naeem SF, Fitzgerald CR, Champine B, Sorensen T. Comparison of Measured Radiation Exposure and Dose Rates with Analytical and Computational Methods. ACS Chemical Health & Safety. 2025;32(3):259-265. doi:10.1021/acs.chas.4c00115

BibTeX
@article{Naeem2025,
  author = {Naeem, Syed F. and Fitzgerald, Christopher R. and Champine, Brian and Sorensen, Tony},
  title = {Comparison of Measured Radiation Exposure and Dose Rates with Analytical and Computational Methods},
  journal = {ACS Chemical Health & Safety},
  year = {2025},
  volume = {32},
  number = {3},
  pages = {259--265},
  doi = {10.1021/acs.chas.4c00115}
}
Kostenlos starten →