EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison

Sean Banaee, Airek Mathews, Shane Que Hee iD

ACS Chemical Health & Safety · 27.05.2024 · 31 (3) · 253-258

DOI: 10.1021/acs.chas.3c00117 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 20.03.2024. Verfasst von Sean Banaee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Health Sciences and UCLA Center for Occupational & Environmental Health, Fielding School of Public Health, University of …. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIOSH CDC HHS, National Institute for Occupational Safety and Health, Center for Occupational and Environmental Health, University of California, Los Angeles.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (A) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm2/min and the steady state permeation rate (SSPR) depended on A, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (p ≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer’s. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available.

Autor:innen und Institutionen

  • Department of Environmental Health Sciences and UCLA Center for Occupational & Environmental Health, Fielding School of Public Health, University of California Los Angeles, 650 Charles E Young Jr Drive South, Los Angele…

ORCID-Profile: Shane Que Hee

Förderung

  • NIOSH CDC HHS
  • National Institute for Occupational Safety and Health
  • Center for Occupational and Environmental Health, University of California, Los Angeles

Zitieren

APA

Banaee, S., Mathews, A., & Que Hee, S. (2024). Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison. ACS Chemical Health & Safety, 31(3), 253-258. https://doi.org/10.1021/acs.chas.3c00117

Vancouver

Banaee S, Mathews A, Que Hee S. Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison. ACS Chemical Health & Safety. 2024;31(3):253-258. doi:10.1021/acs.chas.3c00117

BibTeX
@article{Banaee2024,
  author = {Banaee, Sean and Mathews, Airek and Que Hee, Shane},
  title = {Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison},
  journal = {ACS Chemical Health & Safety},
  year = {2024},
  volume = {31},
  number = {3},
  pages = {253--258},
  doi = {10.1021/acs.chas.3c00117}
}
Kostenlos starten →