EUVIMEDEUVIMED entdecken
Crossref

A FRET-Based Fluorometric Assay for Tracking the Enzymatic Degradation of Poly- l -Lactic Acid

Mahbub Ullah iD, Jordan A Cannon iD, Todd B Reynolds iD, Michael D Best iD

Biomacromolecules · 2026

DOI: 10.1021/acs.biomac.6c01709 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomacromolecules, 2026. Verfasst von Mahbub Ullah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Tennessee, Knoxville, Tennessee37996, United States. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Polymers, Lactic Acid. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Department of Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Protein engineering has recently emerged as a promising strategy for enhancing the enzymatic recycling of bio-based polymers with the aim of replacing non-degradable petroleum-based plastics with biodegradable ones like poly-l-lactic acid (PLLA). However, a significant challenge exists in the evaluation of the biodegradation efficiency of newly developed enzymes. The precise tracking and continuous rate monitoring of the enzyme-catalyzed hydrolysis remain difficult to achieve with a conventional l-lactate assay kit, which provides only endpoint measurements and is therefore decoupled from the real-time degradation process. To address this issue, we introduce a novel Förster Resonance Energy Transfer (FRET)-based PLLA substrate capable of monitoring real-time PLLA degradation. This was achieved by connecting a highly fluorescent amino carbamoyl coumarin (ACC) dye with a quencher (2,4-dinitrophenyl-l-lysine) via a tetrameric oligo-l-lactate chain. Several fluorescence studies demonstrate that this substrate can effectively detect PLLA-degrading enzyme activity by monitoring increased fluorescence due to enzyme-catalyzed hydrolysis of the oligolactate chain and disruption of the intramolecular FRET system. This substrate can be a potent replacement for the conventional l-lactate assay kit as it allows fast and accurate tracking of the enzyme activity toward PLLA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescence Resonance Energy TransferPolymersLactic AcidPolyestersHydrolysisFluorometryCoumarinsFluorescent Dyes

Substanzen

poly(lactide)PolyestersPolymersLactic AcidCoumarinsFluorescent Dyes

Autor:innen und Institutionen

  • Department of Chemistry, University of Tennessee, Knoxville, Tennessee37996, United States.
  • Department of Microbiology, University of Tennessee, Knoxville, Tennessee37996, United States.
  • Circular Biosciences LLC, Knoxville, Tennessee37919, United States.

ORCID-Profile: Mahbub Ullah, Jordan A Cannon, Todd B Reynolds, Michael D Best

Förderung

  • Department of Energy

Zitieren

APA

Ullah, M., Cannon, J. A., Reynolds, T. B., & Best, M. D. (2026). A FRET-Based Fluorometric Assay for Tracking the Enzymatic Degradation of Poly- l -Lactic Acid. Biomacromolecules. https://doi.org/10.1021/acs.biomac.6c01709

Vancouver

Ullah M, Cannon JA, Reynolds TB, Best MD. A FRET-Based Fluorometric Assay for Tracking the Enzymatic Degradation of Poly- l -Lactic Acid. Biomacromolecules. 2026. doi:10.1021/acs.biomac.6c01709

BibTeX
@article{Ullah2026,
  author = {Ullah, Mahbub and Cannon, Jordan A and Reynolds, Todd B and Best, Michael D},
  title = {A FRET-Based Fluorometric Assay for Tracking the Enzymatic Degradation of Poly- l -Lactic Acid},
  journal = {Biomacromolecules},
  year = {2026},
  doi = {10.1021/acs.biomac.6c01709}
}
Kostenlos starten →