Multilayer Fluorescent Immunoassay for Early and Sensitive Dengue Virus Detection Using Host and Viral Biomarkers
Bioconjugate Chemistry · 2025
DOI: 10.1021/acs.bioconjchem.5c00153 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioconjugate Chemistry, 2025. Verfasst von Andrew S Browne und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Center for Diagnostics and Therapeutics, Georgia State University, 788 Petit Science Center, Atlanta, Georgia 30302, United …. Hauptthemen laut MEDLINE: Dengue Virus, Chemokine CXCL10, Dengue, Chemokine CCL2. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAID NIH HHS, University of Massachusetts Lowell, Division of Microbiology and Infectious Diseases.
Abstract (Originalsprache)
Early detection and monitoring of dengue virus (DENV) infections are critical for effective disease management. A comprehensive approach combining viral and host biomarker detection improves diagnostic accuracy. Here, we describe a signal enhancement technique combining fluorescent silica nanoparticles and bioorthogonal chemistries for the ultrasensitive detection of monocyte chemoattractant protein 1 (MCP-1), interferon gamma-induced protein 10 (IP-10), and the viral biomarker nonstructural protein 1 (NS1). Our plate-based sandwich assay enhances signals with multiple layered fluorescent dye-encapsulated nanoparticles. In human serum, the assay achieved a limit of detection (LOD) of 43 pg/mL (∼5.0 nM) for MCP-1, ranging from 100 pg/mL to 100 ng/mL; 66 pg/mL (∼7.6 nM) for IP-10, ranging from 10 pg/mL to 100 ng/mL; and 351 pg/mL (8.6 nM) for NS1, ranging from 100 pg/mL to 10 μg/mL. We also monitored host biomarkers in dengue virus-infected AG129 mice using a Milliplex Mouse Cytokine/Chemokine Magnetic Bead Panel. MCP-1 levels in infected mice ranged from 1000 to 7000 pg/mL (mean: 2911 pg/mL), while uninfected controls showed much lower levels (1-10 pg/mL, mean 7 pg/mL). IP-10 levels ranged from 150 to 300 pg/mL (mean 188 pg/mL) in infected mice and 50-100 pg/mL (mean 69.4 pg/mL) in controls. These results aligned with our multilayered fluorescent assay, demonstrating its potential for sensitive dengue biomarker detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Center for Diagnostics and Therapeutics, Georgia State University, 788 Petit Science Center, Atlanta, Georgia 30302, United States.
- Department of Chemistry, University of Massachusetts Lowell, 520 Olney Science Center, 265 Riverside Street, Lowell, Massachusetts 01854, United States.
- Department of Biology, Petit Science Center, Georgia State University, Atlanta, Georgia 30302, United States.
ORCID-Profile: Mukesh Kumar, Suri S Iyer
Förderung
- NIAID NIH HHS
- University of Massachusetts Lowell
- Division of Microbiology and Infectious Diseases
- Georgia State University
Zitieren
APA
Browne, A. S., Fang, J., Elsharkawy, A., Jia, T., Reboli, E., Luo, Y., Sheng, X., Kumar, M., & Iyer, S. S. (2025). Multilayer Fluorescent Immunoassay for Early and Sensitive Dengue Virus Detection Using Host and Viral Biomarkers. Bioconjugate Chemistry. https://doi.org/10.1021/acs.bioconjchem.5c00153
Vancouver
Browne AS, Fang J, Elsharkawy A, Jia T, Reboli E, Luo Y, et al. Multilayer Fluorescent Immunoassay for Early and Sensitive Dengue Virus Detection Using Host and Viral Biomarkers. Bioconjugate Chemistry. 2025. doi:10.1021/acs.bioconjchem.5c00153
BibTeX
@article{Browne2025,
author = {Browne, Andrew S and Fang, Jieqiong and Elsharkawy, Amany and Jia, Tianwei and Reboli, Evan and Luo, Ying and Sheng, Xiaolin and Kumar, Mukesh and Iyer, Suri S},
title = {Multilayer Fluorescent Immunoassay for Early and Sensitive Dengue Virus Detection Using Host and Viral Biomarkers},
journal = {Bioconjugate Chemistry},
year = {2025},
doi = {10.1021/acs.bioconjchem.5c00153}
}
EUVIMED