Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS
Analytical Chemistry · 19.11.2026
DOI: 10.1021/acs.analchem.6c06150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.11.2026. Verfasst von Mina Nikolić und 4 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek.
Abstract (Originalsprache)
Single cell-inductively coupled plasma-time-of-flightmass spectrometry (SC-ICP-TOF-MS) enables high-throughput quantitative assay of endogenous and exogenous elements in individual cells. However, the low transport efficiency, inversely proportional to the cell size, raises a question: does SC-ICP-MS provide representative sampling of the original cell population, or are smaller cells preferentially measured? In this work, the occurrence and degree of size-dependent sampling bias were evaluated using laser ablation (LA)-ICP-TOF-MS, which enables cell size determination prior to analysis and achieves 100% cell transport efficiency. First, tagging protocols with Ruthenium red (RR) and ASCQ_Ruthenium (ASCQ_Ru) were thoroughly optimized to enable cell size estimation in SC-ICP-MS. To verify that both tags accurately capture size information, an automated LA-ICP-MS data processing pipeline was developed, revealing that the optically measured cell size distribution can be reliably predicted solely from the Ru cell content. This was verified across 4 distinct human cell types of different sizes (10−40 μm) and by analyzing up to 1000 cells per sample. While both tags successfully revealed cell size, ASCQ_Ru produced cleaner transient signals and did not influence the content of endogenous elements (i.e., P, S, Ca, Fe, Cu and Zn), whereas RR produced low-intensity non-cellular events and induced partial losses of Ca and Zn. Finally, the comparison of cell sizes based on LA-SC-ICP-MS and SC-ICP-MS revealed the existence of a slight size-dependent bias with a higher fraction of large cells observed by the former. These findings should be accounted for when developing novel SC-ICP-MS applications to ensure that reliable information is obtained.
Förderung
- Fonds Wetenschappelijk Onderzoek
Zitieren
APA
Nikolić, M., Lores-Padin, A., Acker, T. V., Wever, O. D., & Vanhaecke, F. (2026). Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c06150
Vancouver
Nikolić M, Lores-Padin A, Acker TV, Wever OD, Vanhaecke F. Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c06150
BibTeX
@article{Nikolic2026,
author = {Nikolić, Mina and Lores-Padin, Ana and Acker, Thibaut Van and Wever, Olivier De and Vanhaecke, Frank},
title = {Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c06150}
}