Physically Constrained Inverse-Gaussian Deconvolution of Diffusion-Broadened Drift-Tube Ion Mobility Spectra
Analytical Chemistry · 10.11.2026 · 98 (44) · 31785-31798
DOI: 10.1021/acs.analchem.6c05780 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 16.10.2026. Verfasst von Haoran Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemical Engineering, Xiangtan University, Xiangtan411105, China. Die Arbeit nennt 51 Literaturangaben. Gefördert von: Science and Technology Program of Hunan Province, National Natural Science Foundation of China.
Themen: Mobilisation
Abstract (Originalsprache)
Peak overlap limits chemical assignment in drift-tube ion mobility spectrometry (DT-IMS). Diffusion broadening is commonly modeled with symmetric Gaussian kernels, although a fixed detector records ion first-passage times. We developed an inverse-Gaussian-Nernst-Townsend-Einstein (IG-NTE) deconvolution framework in which the point-spread function (PSF) follows an inverse-Gaussian distribution and its temporal width is constrained by instrument settings through the NTE relation. The resulting drift-time-dependent measurement operator was inverted by nonnegative Richardson-Lucy iteration without peak-width calibration or specification of component number. In simulations, relative to a Gaussian kernel, IG-NTE deconvolution reduced the average full-residual root-mean-square value by 11.4%, the right-tail residual by 18.1%, and the mean absolute peak-area deviation from 5.10% to 1.19%. Applied to a 63Ni DT-IMS instrument, the method separated ethyl 2-methylpentanoate and 1,8-cineole responses 0.040 ms apart while retaining 2,6-di-tert-butylpyridine (DTBP) as a single-component control. It also recovered paired alkyl-pyrazine mobility features consistent with protonation site- and hydration-dependent collision cross sections. In the negative mode, dichloromethane-derived chloride responses assigned to 35Cl− and 37Cl− exhibited a 3.08:1 area ratio and were supported by GC-TOF-MS. These results show that detector-domain transport modeling can improve the effective reconstructed resolution of diffusion-broadened DT-IMS spectra without hardware modification, provided that controls and forward residual analysis are used to assess reconstruction artifacts.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Chemical Engineering, Xiangtan University, Xiangtan411105, China.
ORCID-Profile: Haoran Huang, Wenjie Liu
Förderung
- Science and Technology Program of Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Huang, H., Li, Z., Chen, L., Yu, J., & Liu, W. (2026). Physically Constrained Inverse-Gaussian Deconvolution of Diffusion-Broadened Drift-Tube Ion Mobility Spectra. Analytical Chemistry, 98(44), 31785-31798. https://doi.org/10.1021/acs.analchem.6c05780
Vancouver
Huang H, Li Z, Chen L, Yu J, Liu W. Physically Constrained Inverse-Gaussian Deconvolution of Diffusion-Broadened Drift-Tube Ion Mobility Spectra. Analytical Chemistry. 2026;98(44):31785-31798. doi:10.1021/acs.analchem.6c05780
BibTeX
@article{Huang2026,
author = {Huang, Haoran and Li, Zhicheng and Chen, Lu and Yu, Jianna and Liu, Wenjie},
title = {Physically Constrained Inverse-Gaussian Deconvolution of Diffusion-Broadened Drift-Tube Ion Mobility Spectra},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {44},
pages = {31785--31798},
doi = {10.1021/acs.analchem.6c05780}
}
EUVIMED