EUVIMEDEUVIMED entdecken
Open Access

Post-Column Dead Volume as a Critical Determinant in Low-Input, High-Throughput Proteomics

Chao Wang iD, Hsien-Jung Lavender Lin iD, Thy Truong, Siqi Huang, Ryan T Kelly iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 31712-31720

DOI: 10.1021/acs.analchem.6c05567 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 30.09.2026. Verfasst von Chao Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah84602, United States. Hauptthemen laut MEDLINE: Proteomics, Proteome, High-Throughput Screening Assays. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Post-column dead volume resulting from union-separated emitters and other sources can be a major contributor to extra-column band broadening in nano-flow liquid chromatography, yet its impact across practical configurations has not been studied systematically. Here, we evaluate the impact of post-column dead volume (PCDV) on chromatographic performance and proteome depth by comparing integrated and non-integrated column configurations connected through unions or valves across a broad range of column inner diameters, flow rates and gradient lengths. We show that PCDV effects significantly increase peak widths, particularly for short gradients and low flow rates. Increased PCDV also results in dramatically reduced proteome coverage, particularly for low-input samples. Surprisingly, eliminating PCDV through integrated emitters increased quantitative precision under virtually all tested conditions despite the narrower peaks leading to fewer data points per peak. When using a high-throughput LC platform operated at 288 samples per day (5 min sample-to-sample time), up to 35.8% improvement in proteome coverage was achieved for single-cell proteomics for an integrated emitter relative to a union-connected emitter. These findings underscore the importance of minimizing post-column dead volume for high-sensitivity and high-throughput nanoLC-MS analyses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteomicsProteomeHigh-Throughput Screening AssaysChromatography, LiquidAnimalsHumans

Substanzen

Proteome

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah84602, United States.
  • MicrOmics Technologies, LLC, Spanish Fork, Utah84660, United States.

ORCID-Profile: Chao Wang, Hsien-Jung Lavender Lin, Ryan T Kelly

Förderung

  • NIGMS NIH HHS
  • National Institute of General Medical Sciences

Zitieren

APA

Wang, C., Lavender Lin, H. J., Truong, T., Huang, S., & Kelly, R. T. (2026). Post-Column Dead Volume as a Critical Determinant in Low-Input, High-Throughput Proteomics. Analytical Chemistry, 98(44), 31712-31720. https://doi.org/10.1021/acs.analchem.6c05567

Vancouver

Wang C, Lavender Lin HJ, Truong T, Huang S, Kelly RT. Post-Column Dead Volume as a Critical Determinant in Low-Input, High-Throughput Proteomics. Analytical Chemistry. 2026;98(44):31712-31720. doi:10.1021/acs.analchem.6c05567

BibTeX
@article{Wang2026,
  author = {Wang, Chao and Lavender Lin, Hsien-Jung and Truong, Thy and Huang, Siqi and Kelly, Ryan T},
  title = {Post-Column Dead Volume as a Critical Determinant in Low-Input, High-Throughput Proteomics},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {31712--31720},
  doi = {10.1021/acs.analchem.6c05567}
}
Kostenlos starten →