EUVIMEDEUVIMED entdecken
Crossref

Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography

Luyao Ge, Zhou Shi, Zikai Xie, Jun Jiang, Linjiang Chen, Xiaobo Li

Analytical Chemistry · 14.11.2026

DOI: 10.1021/acs.analchem.6c05466 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 14.11.2026. Verfasst von Luyao Ge und 5 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Science and Technology Major Project, Robotic AI-Scientist Platform of the Chinese Academy of Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chromatographic method development typically resolves peaks before calibration and quantification. Here, we introduce a quantification-guided closed-loop strategy that selects methods by experimentally demonstrated calibration performance rather than baseline separation. The workflow combines automated gas-chromatographic experimentation, simultaneous multicomponent exponentially modified Gaussian fitting, external- or internal-standard calibration, and constrained large-language-model recommendations. The model proposes bounded parameter changes, while deterministic software enforces operating limits, generates executable conditions, and applies predefined acceptance criteria. Across one external-standard and three internal-standard systems containing two to four analytes, selected methods achieved run times of 2.2−2.7 min and minimum analyte-specific R2 values of 0.994−0.999, respectively. In the five-component system, calibration slope RSDs were below 0.30% across five independently prepared calibration series. All 12 analyte-level predictions in three validation mixtures had absolute relative errors below 9%, and mean spike recoveries were 97.61−103.90%. These results indicate that baseline separation need not be universal when overlapping components remain identifiable, and quantitative performance is experimentally verified. More broadly, quantitative validity as a feedback signal moves chromatography from a passive measurement endpoint toward a bounded autonomous process for self-driving laboratories and compositionally bounded high-throughput workflows.

Förderung

  • National Science and Technology Major Project
  • Robotic AI-Scientist Platform of the Chinese Academy of Sciences

Zitieren

APA

Ge, L., Shi, Z., Xie, Z., Jiang, J., Chen, L., & Li, X. (2026). Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c05466

Vancouver

Ge L, Shi Z, Xie Z, Jiang J, Chen L, Li X. Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c05466

BibTeX
@article{Ge2026,
  author = {Ge, Luyao and Shi, Zhou and Xie, Zikai and Jiang, Jun and Chen, Linjiang and Li, Xiaobo},
  title = {Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c05466}
}
Kostenlos starten →