Smartphone-Assisted Electrochemiluminescence Imaging Platform Based on Protamine-Enhanced Gold Nanoclusters for Ultrasensitive and Visualized Detection of Zearalenone
Analytical Chemistry · 22.09.2026 · 98 (37) · 27724-27732
DOI: 10.1021/acs.analchem.6c05205 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 08.09.2026. Verfasst von Tingting Han und 9 weiteren Autor:innen. Beteiligte Einrichtung: Jiangsu Key Laboratory of Food Quality and Safety, Key Laboratory for Control Technology and Standard for Agro-product Safety and Quality, Ministry o…. Hauptthemen laut MEDLINE: Zearalenone, Smartphone, Metal Nanoparticles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Basic Research Program of China (973 Program), National Natural Science Foundation of China (NSFC), Fundamental Research Funds for the Heilongjiang Province Scientific Research Institute.
Abstract (Originalsprache)
Zearalenone (ZEN) contamination in grains poses a serious threat to human and animal health, yet existing imaging-based platforms for rapid visualized detection remain limited by insufficient sensitivity, limited luminescence efficiency, and poor signal stability, hindering further practical applications. Herein, a portable smartphone-assisted electrochemiluminescence (ECL) imaging platform was developed for ultrasensitive and visualized detection of ZEN based on protamine-enhanced 6-aza-2-thiothymine-stabilized gold nanoclusters (Prot/ATT-Au NCs) synthesized by a protein-assisted assembly strategy. The resulting Prot/ATT-Au NCs achieved a 108-fold enhancement in ECL intensity relative to bare ATT-Au NCs and demonstrated an ECL efficiency approximately 5.01-fold higher than that of the benchmark Ru(bpy)32+ system, enabling naked-eye-visible green ECL emission. This enhancement was attributed to Prot-induced hydrogen-bonding and electrostatic confinement that suppressed nonradiative decay and facilitated radiative transitions. Integrated with catalytic hairpin assembly amplification, the developed ECL imaging system allowed ZEN to be visually quantified over a wide linear range of 1 pg/mL to 10 μg/mL with a detection limit of 0.38 pg/mL, along with excellent specificity, stability, reproducibility, and real-sample recoveries. Furthermore, it was applied for the determination of ZEN in naturally contaminated corn samples. This work provides a facile strategy for engineering high-performance ECL emitters and offers a robust route toward portable food safety monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Jiangsu Key Laboratory of Food Quality and Safety, Key Laboratory for Control Technology and Standard for Agro-product Safety and Quality, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy…
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry, Nanjing University, Nanjing210023, PR China.
- Key Laboratory of Quality and Safety of Cereals and Their Products, State Administration for Market Regulation, Quality and Safety Institute of Agricultural Products, Heilongjiang Academy of Agricultural Sciences, Harbi…
- State Key Laboratory of Flexible Electronics (LoFE) & Institute of Advanced Materials (IAM), Nanjing University of Posts & Telecommunications (NJUPT), Nanjing210023, PR China.
ORCID-Profile: Tingting Han, Gang Wang, Yue Cao, Zixuan Chen, Jianhong Xu, Jun-Jie Zhu
Förderung
- National Basic Research Program of China (973 Program)
- National Natural Science Foundation of China (NSFC)
- Fundamental Research Funds for the Heilongjiang Province Scientific Research Institute
- Key Laboratory of Quality and Safety of Cereals and Their Products, State Administration for Market Regulation
- Ministry of Agriculture and Rural Affairs Key Laboratory of Control Technology and Standard for Agroproduct Safety and Quality
- Foundation of State Key Laboratory of Analytical Chemistry for Life Science
Zitieren
APA
Han, T., Zhuang, J., Zhou, K., Zhu, E., Zhao, L., Wang, G., Cao, Y., Chen, Z., Xu, J., & Zhu, J. J. (2026). Smartphone-Assisted Electrochemiluminescence Imaging Platform Based on Protamine-Enhanced Gold Nanoclusters for Ultrasensitive and Visualized Detection of Zearalenone. Analytical Chemistry, 98(37), 27724-27732. https://doi.org/10.1021/acs.analchem.6c05205
Vancouver
Han T, Zhuang J, Zhou K, Zhu E, Zhao L, Wang G, et al. Smartphone-Assisted Electrochemiluminescence Imaging Platform Based on Protamine-Enhanced Gold Nanoclusters for Ultrasensitive and Visualized Detection of Zearalenone. Analytical Chemistry. 2026;98(37):27724-27732. doi:10.1021/acs.analchem.6c05205
BibTeX
@article{Han2026,
author = {Han, Tingting and Zhuang, Jinyang and Zhou, Kai and Zhu, Enwei and Zhao, Lin and Wang, Gang and Cao, Yue and Chen, Zixuan and Xu, Jianhong and Zhu, Jun-Jie},
title = {Smartphone-Assisted Electrochemiluminescence Imaging Platform Based on Protamine-Enhanced Gold Nanoclusters for Ultrasensitive and Visualized Detection of Zearalenone},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {37},
pages = {27724--27732},
doi = {10.1021/acs.analchem.6c05205}
}
EUVIMED