EUVIMEDEUVIMED entdecken
Crossref

Machine-Learning-Driven Dual-Mode Immunoassay Based on Nanobody and Natural Fluorescent Probe for Ultrasensitive Quantification of Pseudomonas aeruginosa

Mengnan Wang, Guangsheng Ge, Xueyi Fan, Kai Zheng, Yuxin Miao, Qing Yao, Min Ma iD, Jianlong Wang iD, Yanru Wang iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c04879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Mengnan Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Engineering, Northwest A&F University, Yangling712100, Shaanxi, China. Hauptthemen laut MEDLINE: Pseudomonas aeruginosa, Fluorescent Dyes, Machine Learning, Single-Domain Antibodies. Die Arbeit nennt 29 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, Shaanxi Provincial Science and Technology Department, Shaanxi Province postdoctoral research project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pseudomonas aeruginosa is a Gram-negative opportunistic bacterial pathogen posing severe threat to environmental safety and human health. To achieve rapid and accurate detection, we developed a nanobody-based colorimetric-fluorescent dual-mode sandwich immunosensor using natural fluorescent probe and further integrated machine learning to enhance the signal readout and improve detection sensitivity. Here, specific nanobodies toward P. aeruginosa were successfully developed for the first time by biopanning against an immune phage-displayed nanobody library. Natural fluorescent quinine, which possesses intrinsic fluorescence and undergoes fluorescence quenching via an internal quenching effect, was employed as the fluorescent probe. With the baseline LODs obtained by direct fitting of the raw optical signals (9.005 × 105 CFU/mL for colorimetry and 3.02 × 103 CFU/mL for fluorescence), an XGBoost model was introduced and further reduces the LOD to 3.269 × 103 CFU/mL and 3.96 × 102 CFU/mL, achieving a 275-fold and 7.6-fold improvement in sensitivity, respectively. Furthermore, following a brief pre-enrichment, this method enables detection of P. aeruginosa at concentrations as low as 10 CFU/mL. Recoveries in water samples ranged from 81.47% to 119.47%, with a coefficient of variation below 8.44%, showing good agreement with machine learning predictions (R2 = 0.957). No cross-reactivity was observed with closely related or heterologous bacteria. This method provides a technical approach for the precise quantitative monitoring of P. aeruginosa in complex environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pseudomonas aeruginosaFluorescent DyesMachine LearningSingle-Domain AntibodiesImmunoassayLimit of DetectionBiosensing TechniquesColorimetry

Substanzen

Fluorescent DyesSingle-Domain Antibodies

Autor:innen und Institutionen

  • College of Food Science and Engineering, Northwest A&F University, Yangling712100, Shaanxi, China.

ORCID-Profile: Min Ma, Jianlong Wang, Yanru Wang

Förderung

  • China Postdoctoral Science Foundation
  • Shaanxi Provincial Science and Technology Department
  • Shaanxi Province postdoctoral research project
  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Wang, M., Ge, G., Fan, X., Zheng, K., Miao, Y., Yao, Q., Ma, M., Wang, J., & Wang, Y. (2026). Machine-Learning-Driven Dual-Mode Immunoassay Based on Nanobody and Natural Fluorescent Probe for Ultrasensitive Quantification of Pseudomonas aeruginosa. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c04879

Vancouver

Wang M, Ge G, Fan X, Zheng K, Miao Y, Yao Q, et al. Machine-Learning-Driven Dual-Mode Immunoassay Based on Nanobody and Natural Fluorescent Probe for Ultrasensitive Quantification of Pseudomonas aeruginosa. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c04879

BibTeX
@article{Wang2026,
  author = {Wang, Mengnan and Ge, Guangsheng and Fan, Xueyi and Zheng, Kai and Miao, Yuxin and Yao, Qing and Ma, Min and Wang, Jianlong and Wang, Yanru},
  title = {Machine-Learning-Driven Dual-Mode Immunoassay Based on Nanobody and Natural Fluorescent Probe for Ultrasensitive Quantification of Pseudomonas aeruginosa},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c04879}
}
Kostenlos starten →