EUVIMEDEUVIMED entdecken
Crossref

Continuously Tuning the Air Plasma Desorption Ambient Ionization Source for Broad Polarity Compound Detection

Feng Liu iD, Huaxue Xie, Jize Duan, Xinglei Zhang, Bin Wang, Shuinan Yu, Dongbo Mi iD, Xiaofeng Dong iD, Shuanglong Wang iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 31172-31185

DOI: 10.1021/acs.analchem.6c04512 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 14.10.2026. Verfasst von Feng Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang330013, China. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangxi Province, Key Research and Development Program of Jiangxi Province, East China Institute of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ambient ionization sources directly analyze different polarity analytes in the samples, but they struggle to simultaneously analyze polar/nonpolar analytes and minimize fragmentation caused by the weakness of controlling the internal energy distribution of the sources. Herein, a plasma desorption ionization (PDI) mass spectrometry (MS) was developed for a continuously controllable internal energy distribution of the ion source, which enables tuning the ionization modes of either proton transfer or charge exchange. By controlling the duty ratio, the PDI was tuned to ionize molecules of different polarity, to minimize fragmentation, and to reduce the matrix effect. Lower duty ratios (1−5%) yield lower Emax with narrow internal energy distributions characteristic of soft ionization, while higher duty ratios (40−100%) produce higher Emax with broad distributions characteristic of hard ionization. Above all, it showed an excellent performance in improving the signal-to-noise ratio by 40-fold. In addition, by coupling this PDI to a portable MS, real-world samples, like 2 polycyclic aromatic hydrocarbons and 25 pharmaceuticals (20 tablets, two liquid medicines, and three salves), were detected within 30 s, and the limit of detection of medicines was as low as 0.15 ng·mL−1. The PDI−MS has promise for applications in high-throughput screening of samples on site.

Autor:innen und Institutionen

  • Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang330013, China.
  • School of Mechanical and Electronic Engineering, East China University of Technology, Nanchang330013, China.
  • Evaluation and Research Center of Dao-di Herbs of Jiangxi Province, GanJiang New Area330000, China.

ORCID-Profile: Feng Liu, Dongbo Mi, Xiaofeng Dong, Shuanglong Wang

Förderung

  • Natural Science Foundation of Jiangxi Province
  • Key Research and Development Program of Jiangxi Province
  • East China Institute of Technology
  • Jiangxi Provincial Department of Science and Technology
  • National Natural Science Foundation of China

Zitieren

APA

Liu, F., Xie, H., Duan, J., Zhang, X., Wang, B., Yu, S., Mi, D., Dong, X., & Wang, S. (2026). Continuously Tuning the Air Plasma Desorption Ambient Ionization Source for Broad Polarity Compound Detection. Analytical Chemistry, 98(44), 31172-31185. https://doi.org/10.1021/acs.analchem.6c04512

Vancouver

Liu F, Xie H, Duan J, Zhang X, Wang B, Yu S, et al. Continuously Tuning the Air Plasma Desorption Ambient Ionization Source for Broad Polarity Compound Detection. Analytical Chemistry. 2026;98(44):31172-31185. doi:10.1021/acs.analchem.6c04512

BibTeX
@article{Liu2026,
  author = {Liu, Feng and Xie, Huaxue and Duan, Jize and Zhang, Xinglei and Wang, Bin and Yu, Shuinan and Mi, Dongbo and Dong, Xiaofeng and Wang, Shuanglong},
  title = {Continuously Tuning the Air Plasma Desorption Ambient Ionization Source for Broad Polarity Compound Detection},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {31172--31185},
  doi = {10.1021/acs.analchem.6c04512}
}
Kostenlos starten →