EUVIMEDEUVIMED entdecken
Crossref

Size/Color Dual-Encoded Electrochemiluminescence for Multiplexed Immunoassay of Cardiac Biomarkers

Weiyu Qu, Chunyan Liu, Li Shen, Jieping Li, Yu Liu, Weiliang Guo iD, Zhihui Dai iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 30981-30990

DOI: 10.1021/acs.analchem.6c04482 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 09.10.2026. Verfasst von Weiyu Qu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Collaborative Innovation Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing2100…. Hauptthemen laut MEDLINE: Luminescent Measurements, Troponin I, Electrochemical Techniques, C-Reactive Protein. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Qinglan Project of Jiangsu Province of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemiluminescence immunoassay (ECLIA) is a powerful analytical method for protein biomarker detection, and plays a critical role in early disease diagnosis and clinical monitoring. However, conventional ECLIA is limited by poor multiplexing capacity, typically allowing only single-target measurement per run. Here, we report a dual-encoded strategy for ECL signal resolution that enables simultaneous determination of multiple biomarkers from a single sample. Four types of magnetic microbeads (MMBs), distinguished by both diameter and fluorescent dye labeling, were employed as solid carriers in a multiplexed sandwich immunoassay format. Three of the bead types have a diameter of 3 μm, while the fourth measures 1.5 μm, allowing the latter to be readily identified by bright-field (BF) imaging based on size. The remaining three 3 μm beads are further differentiated by their fluorescence (FL) colors. By combining this size/color dual-encoding scheme with ECL imaging technology, multiplexed recognition and quantification of biomarkers is achieved. The method was validated by simultaneous detection of four cardiac biomarkers, namely cardiac troponin I (cTnI), C-reactive protein (CRP), D-dimer, and myoglobin (Myo). The multiplexed ECLIA demonstrated a wide linear range spanning to 3 orders of magnitude, with detection limits of 0.0044, 0.55, 0.99, 0.30 ng mL−1 for cTnI, CRP, D-dimer, and Myo, respectively. This work offers a facile route to construct multiplexed ECLIA platforms and holds promise for further enhancement of detection throughput through combined encoding strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Luminescent MeasurementsTroponin IElectrochemical TechniquesC-Reactive ProteinImmunoassayBiomarkersHumansMicrospheresMyoglobinColorParticle Size

Stichwörter der Autor:innen

ECL microscopyElectrochemiluminescencemagnetic microbeadsmultiplexed immunoassaysize/color dual encoding

Substanzen

BiomarkersTroponin IC-Reactive ProteinMyoglobin

Autor:innen und Institutionen

  • Collaborative Innovation Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing210023, China.
  • State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing210023, China.
  • School of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing211816, China.

ORCID-Profile: Weiliang Guo, Zhihui Dai

Förderung

  • Qinglan Project of Jiangsu Province of China
  • National Natural Science Foundation of China

Zitieren

APA

Qu, W., Liu, C., Shen, L., Li, J., Liu, Y., Guo, W., & Dai, Z. (2026). Size/Color Dual-Encoded Electrochemiluminescence for Multiplexed Immunoassay of Cardiac Biomarkers. Analytical Chemistry, 98(44), 30981-30990. https://doi.org/10.1021/acs.analchem.6c04482

Vancouver

Qu W, Liu C, Shen L, Li J, Liu Y, Guo W, et al. Size/Color Dual-Encoded Electrochemiluminescence for Multiplexed Immunoassay of Cardiac Biomarkers. Analytical Chemistry. 2026;98(44):30981-30990. doi:10.1021/acs.analchem.6c04482

BibTeX
@article{Qu2026,
  author = {Qu, Weiyu and Liu, Chunyan and Shen, Li and Li, Jieping and Liu, Yu and Guo, Weiliang and Dai, Zhihui},
  title = {Size/Color Dual-Encoded Electrochemiluminescence for Multiplexed Immunoassay of Cardiac Biomarkers},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {30981--30990},
  doi = {10.1021/acs.analchem.6c04482}
}
Kostenlos starten →