EUVIMEDEUVIMED entdecken
Crossref

Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation

Yichi Zhang iD, Zihe Guo, Langlang Yang, Zihao Li iD, Zhimeng Zhang, Wenping Geng, Zhangbin Ji, Ruiying Wang, Jian He, Xiujian Chou iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 31016-31030

DOI: 10.1021/acs.analchem.6c04410 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 08.10.2026. Verfasst von Yichi Zhang und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China, Taiyuan, Shanxi 030051, China. Hauptthemen laut MEDLINE: Microfluidic Analytical Techniques, Lab-On-A-Chip Devices. Die Arbeit nennt 52 Literaturangaben. Gefördert von: Fund Program for the Scientific Activities of Selected Returned Overseas Professionals in Shanxi Province, National Natural Science Foundation of China (NSFC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional microfluidic particle sorting systems predominantly rely on static, open-loop operational principles, rendering them highly vulnerable to performance deterioration induced by cellular phenotypic heterogeneity and localized hydrodynamic fluctuations. Here, we introduce an adaptive integrated microfluidic system (AIMS) that implements a closed-loop sensing−decision−actuation−verification control framework via on-chip integration of dual-frequency impedance cytometry (IFC) and tunable traveling surface acoustic waves (T-TSAW). An upstream IFC array (1#IFC) performs real-time, label-free electrical interrogation of single-cell dielectric phenotypes. These transient signals are processed in real time by a custom finite-state machine (FSM) algorithm to dynamically modulate the downstream T-TSAW field. Concurrently, a downstream IFC array (2#IFC) performs post-sorting verification and feeds real-time state metrics back to the FSM core. This initiates an adaptive hill-climbing optimization loop to enable continuous acoustic frequency calibration. The system performance was rigorously evaluated using monodisperse polystyrene microspheres and biologically relevant colloidal models. The closed-loop architecture successfully isolated target MCF-7 cells from an erythrocyte-dominated simplified blood model, achieving an acoustic sorting efficiency of 95 ± 1.5% and a purity of 94 ± 2.5%. Furthermore, continuous adaptive sorting of primary mouse immune cell populations (PBMCs and neutrophils) was demonstrated, achieving a sorting efficiency of 92 ± 1.8% and a purity of 93 ± 6.7%. Ultimately, the seamless integration of transient electronic sensing algorithms with multiphysics mechanical actuation establishes a highly robust architectural framework for autonomous microelectromechanical manipulation platforms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microfluidic Analytical TechniquesLab-On-A-Chip DevicesHumansMCF-7 CellsElectric ImpedanceFeedbackAlgorithmsAnimals

Autor:innen und Institutionen

  • State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China, Taiyuan, Shanxi 030051, China.
  • Shanxi Key Laboratory of Ferroelectric Physical Micro-Nano Devices and Systems, North University of China, Taiyuan, Shanxi 030051, China.
  • Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, Shanxi 030051, China.
  • School of Future Science and Engineering, Soochow University, Suzhou215222, China.

ORCID-Profile: Yichi Zhang, Zihao Li, Xiujian Chou

Förderung

  • Fund Program for the Scientific Activities of Selected Returned Overseas Professionals in Shanxi Province
  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Zhang, Y., Guo, Z., Yang, L., Li, Z., Zhang, Z., Geng, W., Ji, Z., Wang, R., He, J., & Chou, X. (2026). Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation. Analytical Chemistry, 98(44), 31016-31030. https://doi.org/10.1021/acs.analchem.6c04410

Vancouver

Zhang Y, Guo Z, Yang L, Li Z, Zhang Z, Geng W, et al. Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation. Analytical Chemistry. 2026;98(44):31016-31030. doi:10.1021/acs.analchem.6c04410

BibTeX
@article{Zhang2026,
  author = {Zhang, Yichi and Guo, Zihe and Yang, Langlang and Li, Zihao and Zhang, Zhimeng and Geng, Wenping and Ji, Zhangbin and Wang, Ruiying and He, Jian and Chou, Xiujian},
  title = {Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {31016--31030},
  doi = {10.1021/acs.analchem.6c04410}
}
Kostenlos starten →