EUVIMEDEUVIMED entdecken
Crossref

Harnessing Plasmonic Cu2− x Se Transducers for Quantitative Near-Infrared II Photothermal Lateral Flow Exosome Detection

Bang Liu iD, Xiaoming Su, Haiyan Chen, Xiaoxin Yang iD, Ming Li iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 30860-30872

DOI: 10.1021/acs.analchem.6c04310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 12.10.2026. Verfasst von Bang Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Central South University, Changsha, Hunan410083, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Exosomes, Copper, Transducers. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China (NSFC), Scientific Research Program of FuRong Laboratory.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photothermal lateral flow assays (PT-LFAs) hold immense promise for advancing point-of-care (POC) diagnostics into the realm of robust, on-site quantitative analysis. However, their clinical translation remains fundamentally constrained by the absence of high-performance photothermal transducers and insufficient analytical sensitivity. Herein, we develop a near-infrared II (NIR-II) PT-LFA biosensor utilizing a NIR-II PT probe for the sensitive photothermal detection of glioblastoma-derived exosomes in serum. The NIR-II PT probe comprises silica-coated Cu2−xSe core−shell nanoparticles conjugated with anti-EGFR monoclonal antibodies. Numerical simulations and experimental investigations collectively demonstrate the superior NIR-II plasmonic and photothermal properties of the Cu2−xSe component within the probe. Integrating this NIR-II PT probe, the biosensor achieves a limit of detection of 0.62 × 107 particles/mL and a broad dynamic detection range of 0.8−1200 × 107 particles/mL via the NIR-II PT readout, markedly outperforming conventional colorimetric detection. Furthermore, the biosensor exhibits reliable detection accuracy and excellent robustness for exosome analysis in complex serum samples. This study underscores the substantial potential of Cu2−xSe photothermal transducers for the development of highly sensitive LFA-based POC diagnostic platforms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesExosomesCopperTransducersHumansInfrared RaysLimit of DetectionGlioblastoma

Stichwörter der Autor:innen

lateral flow immunoassaynear-infrared II detectionphotothermal probesplasmonic photothermal transducerpoint-of-care diagnostics

Substanzen

Copper

Autor:innen und Institutionen

  • School of Materials Science and Engineering, Central South University, Changsha, Hunan410083, China.
  • Department of Dermatology, Xiangya Hospital, Central South University, Changsha, Hunan410008, China.
  • FuRong Laboratory, Changsha, Hunan410078, China.

ORCID-Profile: Bang Liu, Xiaoxin Yang, Ming Li

Förderung

  • National Natural Science Foundation of China (NSFC)
  • Scientific Research Program of FuRong Laboratory

Zitieren

APA

Liu, B., Su, X., Chen, H., Yang, X., & Li, M. (2026). Harnessing Plasmonic Cu2− x Se Transducers for Quantitative Near-Infrared II Photothermal Lateral Flow Exosome Detection. Analytical Chemistry, 98(44), 30860-30872. https://doi.org/10.1021/acs.analchem.6c04310

Vancouver

Liu B, Su X, Chen H, Yang X, Li M. Harnessing Plasmonic Cu2− x Se Transducers for Quantitative Near-Infrared II Photothermal Lateral Flow Exosome Detection. Analytical Chemistry. 2026;98(44):30860-30872. doi:10.1021/acs.analchem.6c04310

BibTeX
@article{Liu2026,
  author = {Liu, Bang and Su, Xiaoming and Chen, Haiyan and Yang, Xiaoxin and Li, Ming},
  title = {Harnessing Plasmonic Cu2− x Se Transducers for Quantitative Near-Infrared II Photothermal Lateral Flow Exosome Detection},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {30860--30872},
  doi = {10.1021/acs.analchem.6c04310}
}
Kostenlos starten →