A Ratiometric Photoelectrochemical Biosensor Based on Polarity Reversal of Photocurrent Caused by Controllable Surface Defect Engineering
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.6c03992 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Jie Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Synthetic and Biotechnology Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: National Basic Research Program of China (973 Program), Equipment Pre-Research Joint Fund Project of the Ministry of Education, Project of Drug Administration of Xizang Autonomous Region.
Abstract (Originalsprache)
Ratiometric photoelectrochemical (PEC) biosensors based on polarity reversal of photocurrent can effectively avoid false positive or negative signals. However, the two different sensing interfaces that generate two photocurrent signals with opposite polarities limit the detection accuracy, and the critical voltage cannot be dynamically adjusted based on varying detection conditions. To address the aforementioned issues, this work employs a surface defect engineering strategy to develop a PEC biosensor based on Fe-modified TiO2 nanorods (TiO2–Fe) with rich oxygen vacancies. From a single sensing interface of this sensor, the polarity of photocurrent can be reversed to obtain two signals, attributed to the new charge transfer pathway provided by oxygen vacancies. Furthermore, the critical voltage is modulated by adjusting Fe loading, electrolyte pH and light intensity, and the corresponding mechanism is elucidated based on semiconductor electrode kinetics. This sensor is successfully applied to the evaluation of glucose levels in human serum. It exhibits excellent accuracy for quantitative analysis with spike recoveries ranging from 96.02% to 103.26% and relative standard deviations between 0.61% and 2.53%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Synthetic and Biotechnology Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi214122, P. R. China.
- Xizang University of Tibetan Medicine, Lhasa850000, P. R. China.
ORCID-Profile: Xuefeng Liu, Gang Shi
Förderung
- National Basic Research Program of China (973 Program)
- Equipment Pre-Research Joint Fund Project of the Ministry of Education
- Project of Drug Administration of Xizang Autonomous Region
Zitieren
APA
Huang, J., Li, Y., Li, X., Zhu, H., Liu, X., Danzeng, Q., Ji, R., & Shi, G. (2026). A Ratiometric Photoelectrochemical Biosensor Based on Polarity Reversal of Photocurrent Caused by Controllable Surface Defect Engineering. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03992
Vancouver
Huang J, Li Y, Li X, Zhu H, Liu X, Danzeng Q, et al. A Ratiometric Photoelectrochemical Biosensor Based on Polarity Reversal of Photocurrent Caused by Controllable Surface Defect Engineering. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03992
BibTeX
@article{Huang2026,
author = {Huang, Jie and Li, Ying and Li, Xin and Zhu, Haiyan and Liu, Xuefeng and Danzeng, Qupei and Ji, Renqing and Shi, Gang},
title = {A Ratiometric Photoelectrochemical Biosensor Based on Polarity Reversal of Photocurrent Caused by Controllable Surface Defect Engineering},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c03992}
}
EUVIMED