Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.6c03954 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Bao-Xuan Xie und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry, Nanjing University, 163 Xianlin Avenue, Nanjing210023, P. R. Chin…. Hauptthemen laut MEDLINE: Biotin, Molecular Imprinting, Temperature. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China (NSFC).
Abstract (Originalsprache)
The streptavidin–biotin system underpins numerous immunoassays for immobilization, labeling, and signal amplification, yet it is highly susceptible to interference from free biotin in biosamples, leading to inaccurate results and potential clinical misdiagnosis. Current countermeasures remain unsatisfactory, as antibody- or streptavidin-based scavenging strategies suffer from limited depletion capacity, poor assay compatibility, or separation-dependent workflows, making them difficult to broadly integrate into automated immunoassays. Herein, we present a rationally engineered nano-trap that ingeniously integrates a biotin-imprinted dendritic mesoporous core with a thermoresponsive shield, enabling efficient elimination of free biotin interference through a “trap-and-lock” strategy. At room temperature, the nano-trap remains in an “open” state, restricting proteins entry while allowing efficient and high-capacity trapping of free biotin, whereas at immunoassay temperature, it switches to a “close” state, firmly locking the captured biotin and preventing its rebinding to streptavidin. The thermoresponsive shield is grafted with phosphorylcholine to suppress protein adsorption, further making the nano-trap highly compatible with complex biosamples. Simply adding a trapping step prior to protein assays on a mainstream immunoassay workstation achieves an outstanding tolerance to free biotin up to 1000 ng/mL. This tolerance not only exceeds the reported biotin tolerance of many commercial immunoassays, including assays optimized for biotin interference, but also substantially covers the serum biotin levels associated with high-dose biotin therapy. The nano-trap is widely applicable to protein assays and compatible with commercial kits and instruments. Thus, this work provides an appealing approach with high translational potential for addressing biotin interference in immunoassays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry, Nanjing University, 163 Xianlin Avenue, Nanjing210023, P. R. China.
- The Affiliated Drum Tower Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing210008, P. R. China.
ORCID-Profile: Zhen Liu
Förderung
- National Natural Science Foundation of China (NSFC)
Zitieren
APA
Xie, B. X., Lin, X., Gao, S., He, J., & Liu, Z. (2026). Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03954
Vancouver
Xie BX, Lin X, Gao S, He J, Liu Z. Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03954
BibTeX
@article{Xie2026,
author = {Xie, Bao-Xuan and Lin, Xiawen and Gao, Song and He, Jian and Liu, Zhen},
title = {Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c03954}
}
EUVIMED