EUVIMEDEUVIMED entdecken
Crossref

Catalytic Immunoassay with Fluorescence-Colorimetric Dual Readout for Highly Sensitive Zika Virion Detection

Ling-Hong Xiong iD, Suibin Huang, Xuewen He iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c03927 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Ling-Hong Xiong und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Suzhou Medical College of Soochow University, Soochow University, Suzhou215123, China. Hauptthemen laut MEDLINE: Zika Virus, Colorimetry, Virion. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Soochow University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Zika virus (ZIKV) infection may induce severe neurological disorders and congenital malformations in pregnant women and fetuses, posing a substantial threat to global public health. Therefore, sensitive, accurate, and convenient detection strategies are essential for early ZIKV diagnosis to block viral transmission and mitigate adverse clinical complications. Herein, a robust fluorescence-colorimetric dual-modal immunoassay was successfully developed for high-performance ZIKV detection based on dual-functional fluorescence nanoprobes grafted with ZIKV antibodies and catalase. The elaborately designed nanoprobes can generate stable fluorescence signals to realize precise fluorescence-based quantitative detection. Meanwhile, the modified catalase can efficiently decompose hydrogen peroxide, thereby modulating the morphological transformation of gold nanoparticles and achieving naked-eye visible plasmonic colorimetric analysis, with a low limit of detection down to 0.85 PFU/μL. Benefiting from the complementary dual-signal outputs and mutual verification mechanism, the proposed method effectively avoids signal interference and detection errors inherent to conventional single-mode assays. Clinical specimen validation verified that this dual-modal immunoassay achieves 100% diagnostic accuracy in practical ZIKV detection. Integrating high sensitivity, visual readout, excellent anti-interference ability, and reliable quantitative performance, this dual-modal sensing platform provides a promising strategy for early clinical diagnosis and epidemiological surveillance of ZIKV infections.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Zika VirusColorimetryVirionImmunoassayHumansFluorescenceMetal NanoparticlesLimit of DetectionGoldCatalysisZika Virus InfectionFluorescent DyesAntibodies, Viral

Substanzen

GoldFluorescent DyesAntibodies, Viral

Autor:innen und Institutionen

  • School of Public Health, Suzhou Medical College of Soochow University, Soochow University, Suzhou215123, China.
  • Southern University of Science and Technology Hospital , Shenzhen518055, China.
  • State Key Laboratory of Bioinspired Interfacial Materials Science, The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University,…

ORCID-Profile: Ling-Hong Xiong, Xuewen He

Förderung

  • National Natural Science Foundation of China
  • Soochow University

Zitieren

APA

Xiong, L. H., Huang, S., & He, X. (2026). Catalytic Immunoassay with Fluorescence-Colorimetric Dual Readout for Highly Sensitive Zika Virion Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03927

Vancouver

Xiong LH, Huang S, He X. Catalytic Immunoassay with Fluorescence-Colorimetric Dual Readout for Highly Sensitive Zika Virion Detection. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03927

BibTeX
@article{Xiong2026,
  author = {Xiong, Ling-Hong and Huang, Suibin and He, Xuewen},
  title = {Catalytic Immunoassay with Fluorescence-Colorimetric Dual Readout for Highly Sensitive Zika Virion Detection},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c03927}
}
Kostenlos starten →