EUVIMEDEUVIMED entdecken
Crossref

Multi-Collector Extreme Ultraviolet Laser Mass Spectrometry (MC-EUV-MS): Using High-Energy Photoionization for High-Spatial-Resolution Isotope Ratio Mapping of Actinide Materials

Lydia A Rush iD, Matthew A Coble, Carmen S Menoni, Andrew M Duffin iD

Analytical Chemistry · 10.11.2026 · 98 (44) · 30549-30559

DOI: 10.1021/acs.analchem.6c03668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.10.2026. Verfasst von Lydia A Rush und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pacific Northwest National Laboratory , Richland, Washington99354, United States. Die Arbeit nennt 53 Literaturangaben. Gefördert von: U.S. Department of Energy (DOE) by Battelle Memorial Institute, U.S. Department of Homeland Security, Open Call Laboratory Directed Research and Development (LDRD) Program at Pacific Northwest National Laboratory (PNNL).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Isotope maps are typically collected with a multi-collector mass spectrometer (MC-MS) coupled to a high-spatial-resolution ionization source, yet few ionization sources compatible with MC-MS systems can operate robustly at the submicron scale. To meet this need, we couple an extreme ultraviolet (EUV) laser photon-based ionization source to a modified Thermo Scientific NeptunePlus MC-MS by removing and replacing the inductively coupled plasma (ICP) with the EUV laser system, herein called the MC-EUV-MS. The 46.9 nm EUV laser light is focused to sub-micrometer spots for sample ablation while simultaneously realizing high-energy photoionization using 26.4 eV photons. Thus, the EUV probe combines ablation and ionization in a single pulse. We characterize the newly built MC-EUV-MS by analyzing different actinide-bearing materials. We achieve a sample utilization efficiency (SUE) of 0.006% for 238U using the NIST 610 and 612 glasses at a low +2 kV extraction voltage for accelerating ions off the sample. Higher extraction voltages up to +5 kV point to increased ion yields. We measure 235U/238U isotope ratios from three uranium samples ranging from natural to low enriched. We demonstrate the high spatial resolution of the MC-EUV-MS by mapping uranium oxide microparticles using 500 nm ablation spots. Compared to isotope maps collected over the same sample area using large geometry secondary ion mass spectrometry, the MC-EUV-MS shows significantly higher spatial resolution within the scope of this study.

Autor:innen und Institutionen

  • Pacific Northwest National Laboratory , Richland, Washington99354, United States.
  • Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, Colorado80523, United States.

ORCID-Profile: Lydia A Rush, Andrew M Duffin

Förderung

  • U.S. Department of Energy (DOE) by Battelle Memorial Institute
  • U.S. Department of Homeland Security
  • Open Call Laboratory Directed Research and Development (LDRD) Program at Pacific Northwest National Laboratory (PNNL)

Zitieren

APA

Rush, L. A., Coble, M. A., Menoni, C. S., & Duffin, A. M. (2026). Multi-Collector Extreme Ultraviolet Laser Mass Spectrometry (MC-EUV-MS): Using High-Energy Photoionization for High-Spatial-Resolution Isotope Ratio Mapping of Actinide Materials. Analytical Chemistry, 98(44), 30549-30559. https://doi.org/10.1021/acs.analchem.6c03668

Vancouver

Rush LA, Coble MA, Menoni CS, Duffin AM. Multi-Collector Extreme Ultraviolet Laser Mass Spectrometry (MC-EUV-MS): Using High-Energy Photoionization for High-Spatial-Resolution Isotope Ratio Mapping of Actinide Materials. Analytical Chemistry. 2026;98(44):30549-30559. doi:10.1021/acs.analchem.6c03668

BibTeX
@article{Rush2026,
  author = {Rush, Lydia A and Coble, Matthew A and Menoni, Carmen S and Duffin, Andrew M},
  title = {Multi-Collector Extreme Ultraviolet Laser Mass Spectrometry (MC-EUV-MS): Using High-Energy Photoionization for High-Spatial-Resolution Isotope Ratio Mapping of Actinide Materials},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {30549--30559},
  doi = {10.1021/acs.analchem.6c03668}
}
Kostenlos starten →