Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 20.10.2026. Verfasst von Priscilla Nhan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen45141, Germany. Die Arbeit nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Comprehensive two-dimensional chromatography substantially enhances separation performance prior to mass spectrometric detection compared to conventional one-dimensional approaches. This results in (i) cleaner and more readily interpretable mass spectra and (ii) reduced ion suppression in atmospheric pressure ionization sources. To further increase separation performance within a reasonable total analysis time, comprehensive LC×LC was coupled to a SLIM-IM-qTOF-MS system for the analysis of complex herbal liqueur samples. To facilitate the processing of multidimensional data, a long modulation time of 4 min was applied. In addition, trap-based modulation was implemented to improve analyte focusing and optimize two-dimensional pre-separation. A peak capacity of LC×LCn = 201 was achieved for the LC×LC separation. Incorporating ion mobility as a third separation dimension further increased the total peak capacity. Total peak capacities of Ptotal(SLIM) = 16,683 and Ptotal(DTIMS) = 8643 were achieved for the SLIM and DTIMS coupling, respectively. The SLIM coupling therefore provided an approximately 1.9-fold higher total peak capacity than the DTIMS coupling, demonstrating its superior separation potential.

Autor:innen und Institutionen

  • Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen45141, Germany.
  • Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstrasse 5, Essen45141, Germany.

ORCID-Profile: Sven W Meckelmann, Oliver J Schmitz

Zitieren

APA

Nhan, P., Thom, C., Meckelmann, S. W., & Schmitz, O. J. (2026). Ultra-High Peak Capacity Exceeding 5 Peaks per Second Enabled by LC×LC-SLIM-qTOF-MS for the Analysis of Complex Samples. Analytical Chemistry, 98(44), 30764-30774. https://doi.org/10.1021/acs.analchem.6c03659

Vancouver

Nhan P, Thom C, Meckelmann SW, Schmitz OJ. Ultra-High Peak Capacity Exceeding 5 Peaks per Second Enabled by LC×LC-SLIM-qTOF-MS for the Analysis of Complex Samples. Analytical Chemistry. 2026;98(44):30764-30774. doi:10.1021/acs.analchem.6c03659

BibTeX
@article{Nhan2026,
  author = {Nhan, Priscilla and Thom, Cedric and Meckelmann, Sven W and Schmitz, Oliver J},
  title = {Ultra-High Peak Capacity Exceeding 5 Peaks per Second Enabled by LC×LC-SLIM-qTOF-MS for the Analysis of Complex Samples},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {44},
  pages = {30764--30774},
  doi = {10.1021/acs.analchem.6c03659}
}
Kostenlos starten →