Core−Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay
Analytical Chemistry · 10.11.2026 · 98 (44) · 30492-30501
DOI: 10.1021/acs.analchem.6c03489 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 07.10.2026. Verfasst von Xiaopan Cui und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, University of Jinan, Jinan250022, P. R. China. Hauptthemen laut MEDLINE: Keratin-19, Colorimetry, Electrochemical Techniques, Antigens, Neoplasm. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
A novel dual-mode immunosensing platform integrating photoelectrochemical (PEC) and colorimetric detection was developed for the early and reliable determination of the non-small cell lung cancer biomarker cytokeratin 19 fragment (Cyfra21-1). An ordered ReS2/In2S3 type-II heterojunction array was constructed, which not only enlarged the effective electroactive surface area but also introduced an interfacial built-in electric field. As a result, the separation and directional transport of photogenerated charge carriers were significantly promoted, leading to markedly enhanced photoelectric conversion efficiency. In addition, ZIF-67@CoFePBA nanozymes with peroxidase-like activity were employed as dual-function signal probes. Under the PEC detection mode, the photocurrent signal was significantly suppressed during the immunorecognition process, as the steric hindrance effect induced by ZIF-67@CoFePBA nanozymes inhibited the effective migration of photogenerated charge carriers, thereby enabling the quantitative determination of Cyfra21-1. Good linear analytical performance was achieved over a concentration range from 100 fg/mL to 50 ng/mL, with a detection limit of 66.5 fg/mL. Meanwhile, under the colorimetric detection mode, the ZIF-67@CoFePBA nanozymes catalyzed the 3,3′,5,5′-tetramethylbenzidine (TMB)/H2O2 reaction to generate a visually distinguishable colorimetric signal. A good linear response was obtained in the concentration range of 0.5−25 ng/mL, with a detection limit of 0.14 ng/mL. The dual-signal output endowed the platform with an intrinsic self-validation capability through cross-verification of two independent yet correlated signal channels, thereby effectively minimizing false responses induced by environmental interference. This provides a promising analytical strategy for lung cancer biomarker detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan250022, P. R. China.
- School of Water Conservancy and Environment, University of Jinan, Jinan250022, P. R. China.
- Department of Chemistry, Sungkyunkwan University, Suwon16419, Republic of Korea.
ORCID-Profile: Dawei Fan, Yu Du, Huan Wang, Yuyang Li, Qin Wei, Dan Wu
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
Zitieren
APA
Cui, X., Jiang, Y., Fan, D., Du, Y., Wang, H., Li, Y., Wei, Q., & Wu, D. (2026). Core−Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay. Analytical Chemistry, 98(44), 30492-30501. https://doi.org/10.1021/acs.analchem.6c03489
Vancouver
Cui X, Jiang Y, Fan D, Du Y, Wang H, Li Y, et al. Core−Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay. Analytical Chemistry. 2026;98(44):30492-30501. doi:10.1021/acs.analchem.6c03489
BibTeX
@article{Cui2026,
author = {Cui, Xiaopan and Jiang, Yinpeng and Fan, Dawei and Du, Yu and Wang, Huan and Li, Yuyang and Wei, Qin and Wu, Dan},
title = {Core−Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {44},
pages = {30492--30501},
doi = {10.1021/acs.analchem.6c03489}
}
EUVIMED