A Reliable Ratiometric Fluorescent Probe for the Quantification of Mitochondrial Peroxynitrite in Cells and Tissues
Analytical Chemistry · 10.11.2026 · 98 (44) · 30398-30405
DOI: 10.1021/acs.analchem.6c03303 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 14.10.2026. Verfasst von Xiaodi Rong und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Water Conservancy and Environment, University of Jinan, Jinan250022, China. Hauptthemen laut MEDLINE: Peroxynitrous Acid, Mitochondria, Fluorescent Dyes. Die Arbeit nennt 44 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Peroxynitrite (ONOO−) is a reactive oxygen species predominantly generated in mitochondria. Its concentration-dependent dynamics exhibit complex bidirectional effects, making quantitative measurement essential for understanding its pathological roles. Despite advances in fluorescent probes for ONOO− imaging, design limitations and interference from complex cellular environments still compromise detection reliability. Herein, we report the first reliable ratiometric fluorescent probe RDC for quantitative detection of ONOO− in mitochondria. Under single-wavelength excitation, the probe exhibits two emission peaks at 563 nm and 690 nm. Upon reaction with ONOO−, the 690 nm signal remains constant as an internal reference, while the 563 nm signal increases significantly, allowing the ratio (F563/F690) to achieve quantitative detection. The probe exhibits excellent selectivity and high sensitivity (LOD = 96 nM). Cell imaging reveals a linear relationship between the ratiometric signal and exogenous ONOO− concentration, validating its quantitative capability in living cells. Moreover, during pyroptosis, the probe reveals a marked increase in mitochondrial ONOO− levels, which is reversed by a pyroptosis inhibitor, indicating ONOO− as a key effector in pyroptosis. The probe also enables ONOO− detection in tissue samples, demonstrating its potential in complex biological systems. This probe serves as a reliable tool for quantifying mitochondrial ONOO− in cells and tissues and for studying its roles in pyroptosis and related diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Water Conservancy and Environment, University of Jinan, Jinan250022, China.
- School of Life Sciences and Medicine, Shandong University of Technology, Zibo255000, China.
ORCID-Profile: Caiyun Liu, Zhongpeng Wang, Wei Shu, Baocun Zhu
Förderung
- Natural Science Foundation of Shandong Province
- National Natural Science Foundation of China
Zitieren
APA
Rong, X., Liu, C., Xue, B., Hou, F., Wang, Z., Shu, W., & Zhu, B. (2026). A Reliable Ratiometric Fluorescent Probe for the Quantification of Mitochondrial Peroxynitrite in Cells and Tissues. Analytical Chemistry, 98(44), 30398-30405. https://doi.org/10.1021/acs.analchem.6c03303
Vancouver
Rong X, Liu C, Xue B, Hou F, Wang Z, Shu W, et al. A Reliable Ratiometric Fluorescent Probe for the Quantification of Mitochondrial Peroxynitrite in Cells and Tissues. Analytical Chemistry. 2026;98(44):30398-30405. doi:10.1021/acs.analchem.6c03303
BibTeX
@article{Rong2026,
author = {Rong, Xiaodi and Liu, Caiyun and Xue, Bing and Hou, Fengli and Wang, Zhongpeng and Shu, Wei and Zhu, Baocun},
title = {A Reliable Ratiometric Fluorescent Probe for the Quantification of Mitochondrial Peroxynitrite in Cells and Tissues},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {44},
pages = {30398--30405},
doi = {10.1021/acs.analchem.6c03303}
}
EUVIMED