EUVIMEDEUVIMED entdecken
Crossref

Apparent pH Sensitivity of Non-Functionalized Graphene FETs Originates from Faradaic Reactions at the Gold Gate

Shuo Wang, Min Zhang, Zebin Kong, Lanlai Wang, Kunshu Wang, Han Chen, Pengfei Lian

Analytical Chemistry · 14.11.2026

DOI: 10.1021/acs.analchem.6c03272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 14.11.2026. Verfasst von Shuo Wang und 6 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Shanghai Institute of Aerospace.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Graphene field-effect transistors (GFETs) with solid-state gold gate electrodes have recently been used for accurate chemical analysis in complex matrices, yet the mechanistic origin of their pH sensitivity is not fully understood. Here we show that replacing only the gate electrode transforms an otherwise pH-insensitive graphene device into a pH-sensitive one. Using the same high-quality, low-defect CVD graphene as the channel, devices gated with a conventional Ag|AgCl reference electrode exhibit negligible pH sensitivity, while gold-gated devices show a response of −62.7 mV pH−1 at a gate voltage scan rate of 0.3 V s−1. Chronoamperometry distinguishes the transient charging current from the subsequent Faradaic contribution. Cyclic voltammetry and scan-rate-dependent measurements support a coupled Faradaic mechanism. The gate leakage current scales with the square root of the gate voltage scan rate (v), whereas the Dirac-point voltage varies approximately linearly with v1/2 and has a non-zero intercept. Independent open-circuit potential (OCP) measurements confirm that the Au gate itself is pH sensitive and relaxes slowly toward a stable potential. The GFET sensitivity decreases in magnitude at lower scan rates, and extrapolation as the scan rate approaches zero brings it closer to the OCP sensitivity. The remaining difference may reflect the different electrochemical conditions at the Au gate under bias and at open circuit. These findings indicate that the apparent pH response in Au-gated GFETs originates from gate-electrode electrochemistry and is read out through field-effect modulation of the graphene channel.

Förderung

  • Shanghai Institute of Aerospace

Zitieren

APA

Wang, S., Zhang, M., Kong, Z., Wang, L., Wang, K., Chen, H., & Lian, P. (2026). Apparent pH Sensitivity of Non-Functionalized Graphene FETs Originates from Faradaic Reactions at the Gold Gate. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03272

Vancouver

Wang S, Zhang M, Kong Z, Wang L, Wang K, Chen H, et al. Apparent pH Sensitivity of Non-Functionalized Graphene FETs Originates from Faradaic Reactions at the Gold Gate. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03272

BibTeX
@article{Wang2026,
  author = {Wang, Shuo and Zhang, Min and Kong, Zebin and Wang, Lanlai and Wang, Kunshu and Chen, Han and Lian, Pengfei},
  title = {Apparent pH Sensitivity of Non-Functionalized Graphene FETs Originates from Faradaic Reactions at the Gold Gate},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c03272}
}
Kostenlos starten →