EUVIMEDEUVIMED entdecken
Crossref

Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat

Yanan Luan, Yi Huang, Mingze Ma iD, Dan Jiang iD, Dongliu Xiang, Qing Wang iD, Jin Huang iD, Xiaohai Yang iD, Kemin Wang iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c03183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Yanan Luan und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engi…. Hauptthemen laut MEDLINE: Sweat, Hydrocortisone, Wearable Electronic Devices, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China (NSFC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sweat is rich in various biomarkers, including metabolites, hormones, and inorganic ions, and thus, it provides a wealth of physiological information. The real-time monitoring of these biomarkers preserves critical dynamic physiological data, enabling a more comprehensive assessment of the health status. For a sensor, it is desirable to maintain a strong affinity between the recognition probe and the targets while retaining reversible binding. However, these two properties are often mutually contradictory since strong affinity usually gives rise to slow or irreversible dissociation. To address this issue, we developed a microfluidic chip integrated with a chronosampling function. It can collect sweat at different time points, achieving the dynamic detection of cortisol levels in sweat. The chip was integrated with a series of valves prepared with filter paper containing polymers of varying concentrations. These polymers in valves were dissolved in sweat and sequentially opened, allowing the collection and detection of sweat samples from distinct periods. The sampling temporal window spans 0–90 min, generally meeting the requirements for sweat monitoring during most exercises. Additionally, the partitioned design of the main and branch channels in the microfluidic chip effectively prevents cross-contamination among the sweat samples. This wearable microfluidic chip successfully detected sweat cortisol at different time points during the volunteer exercise.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatHydrocortisoneWearable Electronic DevicesLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesHumans

Substanzen

Hydrocortisone

Autor:innen und Institutionen

  • State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha410082, China.
  • Jiangxi Province Key Laboratory of Drug Molecular Design and Evaluation, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, Jiangxi330013, China.

ORCID-Profile: Mingze Ma, Dan Jiang, Qing Wang, Jin Huang, Xiaohai Yang, Kemin Wang

Förderung

  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Luan, Y., Huang, Y., Ma, M., Jiang, D., Xiang, D., Wang, Q., Huang, J., Yang, X., & Wang, K. (2026). Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03183

Vancouver

Luan Y, Huang Y, Ma M, Jiang D, Xiang D, Wang Q, et al. Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03183

BibTeX
@article{Luan2026,
  author = {Luan, Yanan and Huang, Yi and Ma, Mingze and Jiang, Dan and Xiang, Dongliu and Wang, Qing and Huang, Jin and Yang, Xiaohai and Wang, Kemin},
  title = {Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c03183}
}
Kostenlos starten →