EUVIMEDEUVIMED entdecken
Open Access

Point-of-Care Radiation Biodosimetry via a Body-Heated Reverse Transcription-Recombinase Polymerase Amplification Coupled to a Paper-Based Vertical Flow Immunoassay

Ashkan Khanishayan iD, Jerome Lacombe iD, Jasmine Pramila Devadhasan, Alexander Jarrett Summers iD, Matthew W Barrett, James Helton, Frederic Zenhausern

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c03074 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Ashkan Khanishayan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, 475 North Fifth Street, Phoenix, Arizona85004, Un…. Hauptthemen laut MEDLINE: Radiometry, Point-of-Care Systems, Paper, Recombinases. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Desert Mountain CARE, National Institute of Allergy and Infectious Diseases, NIAID NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid biodosimetry at the point of care is critical for efficient triage and clinical management during mass-casualty radiological events. Here, we introduce a power-free biodosimetry platform integrating one-step reverse transcription recombinase polymerase amplification (RT-RPA) with vertical flow immunoassay (VFI) for the multiplex detection of two radiation-responsive transcripts (CDKN1A and DDB2) and housekeeping gene (MRPS5) from fingerstick blood. One-step RT-RPA showed optimal efficiency at 36 °C for 20 min, comparable to two-step RT-RPA and standard PCR. This temperature could be provided by the human body, where the axilla delivered a stable heat source (36.2 °C) with minimal interindividual variability across a range of environmental conditions (from 4 to 42 °C), supporting amplification comparable to thermocycler-based reactions. Amplified products were detected using a capillary-driven VFI platform. The assay demonstrated strong specificity, uniform signal distribution, and reproducibility with intra- and interassay coefficient of variation below 10% and 15%, respectively, across all three transcripts. When applied to ex vivo X-ray irradiated blood samples (1 and 2 Gy), a dose-dependent increase in CDKN1A and DDB2 signals was observed. Receiver operating characteristic analysis demonstrated that discrimination between sham- and 1 Gy-irradiated was not significant, whereas the assay distinguished sham- from 2 Gy-irradiated with area under the curve values of 0.82 (95% CI = [0.66–0.98]; p = 0.0052) and 0.89 (95% CI = [0.76–1.00]; p = 0.0006) for CDKN1A and DDB2, yielding sensitivity/specificity of 84.62%/69.23% and 92.31%/84.62%, respectively. These findings supported the feasibility of the body-heat one-step RT-RPA VFI as a rapid, equipment-free, field-deployable triage tool for large-scale radiation biodosimetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryPoint-of-Care SystemsPaperRecombinasesHumansImmunoassayRapid Diagnostic TestsReverse Transcription

Substanzen

Recombinases

Autor:innen und Institutionen

  • Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, 475 North Fifth Street, Phoenix, Arizona85004, United States.
  • Department of Basic Medical Sciences; College of Medicine Phoenix, University of Arizona, 425 N Fifth Street, Phoenix, Arizona85004, United States.
  • Department of Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, Arizona85721, United States.
  • HonorHealth Research Institute, Scottsdale, Arizona85258, United States.

ORCID-Profile: Ashkan Khanishayan, Jerome Lacombe, Alexander Jarrett Summers

Förderung

  • Desert Mountain CARE
  • National Institute of Allergy and Infectious Diseases
  • NIAID NIH HHS
  • NASA
  • National Aeronautics and Space Administration

Zitieren

APA

Khanishayan, A., Lacombe, J., Devadhasan, J. P., Summers, A. J., Barrett, M. W., Helton, J., & Zenhausern, F. (2026). Point-of-Care Radiation Biodosimetry via a Body-Heated Reverse Transcription-Recombinase Polymerase Amplification Coupled to a Paper-Based Vertical Flow Immunoassay. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03074

Vancouver

Khanishayan A, Lacombe J, Devadhasan JP, Summers AJ, Barrett MW, Helton J, et al. Point-of-Care Radiation Biodosimetry via a Body-Heated Reverse Transcription-Recombinase Polymerase Amplification Coupled to a Paper-Based Vertical Flow Immunoassay. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03074

BibTeX
@article{Khanishayan2026,
  author = {Khanishayan, Ashkan and Lacombe, Jerome and Devadhasan, Jasmine Pramila and Summers, Alexander Jarrett and Barrett, Matthew W and Helton, James and Zenhausern, Frederic},
  title = {Point-of-Care Radiation Biodosimetry via a Body-Heated Reverse Transcription-Recombinase Polymerase Amplification Coupled to a Paper-Based Vertical Flow Immunoassay},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c03074}
}
Kostenlos starten →