EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Nanoelectroanalysis with Carbon Nanopipettes Based on Prussian Blue-NiHCF for Hydrogen Peroxide Sensing

Antonino Biagio Carbonaro, Gregorio Laucirica, Gastón A Crespo iD, María Cuartero iD

Analytical Chemistry · 04.08.2026 · 98 (30) · 22348-22358

DOI: 10.1021/acs.analchem.6c02551 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 25.06.2026. Verfasst von Antonino Biagio Carbonaro und 3 weiteren Autor:innen. Beteiligte Einrichtung: UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech , Avda. Andrés Hernández Ros, 1, Murcia30107, Spain. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 European Research Council, Ministerio de Ciencia, Innovación y Universidades, European Social Fund Plus.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Carbon nanopipettes (CNPs) have emerged as powerful tools to track intracellular redox processes with high spatial resolution. Their implementation for robust H2O2 sensing, however, is still limited by stability and mechanistic constraints largely attributed to the surface chemistry of the electrode under nanoconfinement. To address this challenge, we report for the first time a combination of Prussian Blue–Nickel hexacyanoferrate (PB-NiHCF) modified carbon nanopipettes for the electrochemical detection of H2O2 under nanoconfined conditions. Electrodeposition strategies and stabilization protocols for the growth of PB-NiHCF thin films are thoroughly inspected. Cyclic voltammetry and double-potential step chronoamperometry (DPSC) are used to rationalize the thin-layer regime established within the nanometric inner tip of the CNPs. Attention is devoted to the nature and catalytic properties of the electrodeposited materials, which are key factors governing the sensing performance. Notably, both the open-circuit potential of the modified nanopipette and the management of the applied potential at the working electrode prove crucial for the detection mechanism. The analytical performance of the system is evaluated by DPSC, demonstrating stable sensing and a linear response up to 500 μM H2O2 (R2 = 0.996), with a limit of detection of 28.9 μM at physiological pH, supporting further in vivo single-cell analysis. Overall, this work provides an analytical framework for H2O2 detection in thin-layer electrochemical cells, opening new perspectives for nanoscale electroanalysis in confined environments and coulometric sensor development.

Autor:innen und Institutionen

  • UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech , Avda. Andrés Hernández Ros, 1, Murcia30107, Spain.
  • Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, StockholmSE-114 28, Sweden.

ORCID-Profile: Gastón A Crespo, María Cuartero

Förderung

  • H2020 European Research Council
  • Ministerio de Ciencia, Innovación y Universidades
  • European Social Fund Plus
  • Ministerio de Ciencia, Innovaci?n y Universidades

Zitieren

APA

Carbonaro, A. B., Laucirica, G., Crespo, G. A., & Cuartero, M. (2026). Nanoelectroanalysis with Carbon Nanopipettes Based on Prussian Blue-NiHCF for Hydrogen Peroxide Sensing. Analytical Chemistry, 98(30), 22348-22358. https://doi.org/10.1021/acs.analchem.6c02551

Vancouver

Carbonaro AB, Laucirica G, Crespo GA, Cuartero M. Nanoelectroanalysis with Carbon Nanopipettes Based on Prussian Blue-NiHCF for Hydrogen Peroxide Sensing. Analytical Chemistry. 2026;98(30):22348-22358. doi:10.1021/acs.analchem.6c02551

BibTeX
@article{Carbonaro2026,
  author = {Carbonaro, Antonino Biagio and Laucirica, Gregorio and Crespo, Gastón A and Cuartero, María},
  title = {Nanoelectroanalysis with Carbon Nanopipettes Based on Prussian Blue-NiHCF for Hydrogen Peroxide Sensing},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {30},
  pages = {22348--22358},
  doi = {10.1021/acs.analchem.6c02551}
}
Kostenlos starten →