Length-Dependent Behavior of Linear dsDNA in IP-RP-HPLC on Supermacroporous Polymer Resin
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.6c02096 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Simonas Balčiu̅nas und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225Vilnius, Lithuania. Hauptthemen laut MEDLINE: DNA, Chromatography, Reverse-Phase, Polystyrenes. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Ion-pair reversed-phase high performance liquid chromatography (IP-RP-HPLC) is widely employed for the characterization of therapeutic oligonucleotides and mRNA vaccines. However, the retention behavior of linear double-stranded DNA (dsDNA), especially very large fragments, is not well-defined under IP-RP-HPLC conditions. This work systematically evaluates separations of dsDNA from 35 bp to 20 kbp using a monodisperse supermacroporous polystyrene-divinylbenzene polymer resin. Various parameters, including column length, flow rate, temperature, and ion-pairing reagent were investigated under fixed and varied gradient profiles, to determine their impact on dsDNA retention. A size-dependent behavior emerged, with a practical threshold near 1.5 kbp. Smaller fragments (≤1.5 kbp) exhibited traditional on–off IP-RP-HPLC behavior. Under fixed gradients, higher flow rates together with shorter columns and shallow gradients yielded the highest resolution and peak capacity values. Stronger ion-pairing reagents and elevated temperatures further increased retention and improved resolution in this range. Beyond this length threshold, behavior became less uniform, and the largest fragments (≥5.0 kbp) showed the opposite trend: longer columns, steep gradients, and lower flow rates improved resolution. In contrast to smaller fragments, weaker ion-pairing reagents provided better separations for large dsDNA, with pair-specific optima that depended on temperature and flow. Additionally, very large fragments exhibited measurable retention and resolution even in the absence of IP-RP-driven retention. This supports the presence of a secondary retention mechanism, which is concurrently present during IP-RP-HPLC separation of large dsDNA. These results demonstrate size-dependent duality of dsDNA and provide practical guidelines for IP-RP-HPLC method optimization for both small and large dsDNA molecules.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225Vilnius, Lithuania.
- Thermo Fisher Scientific Baltics, V. A. Graičiu̅no 8, LT-02241Vilnius, Lithuania.
- Thermo Fisher Scientific , Dornierstraße 4, 82110, Germering, Germany.
- State Research Institute Center for Physical Sciences and Technology, Saulėtekio av. 3, LT-10257Vilnius, Lithuania.
ORCID-Profile: Simonas Balčiu̅nas
Zitieren
APA
Balčiu̅nas, S., Žvirblis, A., Damonskis, M., Steiner, F., Naujalis, E., & Taujenis, L. (2026). Length-Dependent Behavior of Linear dsDNA in IP-RP-HPLC on Supermacroporous Polymer Resin. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c02096
Vancouver
Balčiu̅nas S, Žvirblis A, Damonskis M, Steiner F, Naujalis E, Taujenis L. Length-Dependent Behavior of Linear dsDNA in IP-RP-HPLC on Supermacroporous Polymer Resin. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c02096
BibTeX
@article{Baliunas2026,
author = {Balčiu̅nas, Simonas and Žvirblis, Audrius and Damonskis, Matas and Steiner, Frank and Naujalis, Evaldas and Taujenis, Lukas},
title = {Length-Dependent Behavior of Linear dsDNA in IP-RP-HPLC on Supermacroporous Polymer Resin},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c02096}
}
EUVIMED