EUVIMEDEUVIMED entdecken
Crossref

Integrated Optical Sensing and Source-Tracing Model Resolves Formaldehyde Exposure: Precisely Identifying Multiple Coexisting Carcinogenic Sources Indoors

Zaiwei Wang, Chengzhi Xing, Yue Yang, Wanchao Ma, Zhongmou Sun, Huawei Xie, Hongfei Wang, Cheng Liu

Analytical Chemistry · 20.11.2026

DOI: 10.1021/acs.analchem.6c01846 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 20.11.2026. Verfasst von Zaiwei Wang und 7 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Hefei Institutes of Physical Science, Chinese Academy of Sciences, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Indoor formaldehyde (HCHO) is classified as a group 1 carcinogen by the World Health Organization (WHO), and long-term exposure can cause diseases such as leukemia. It is one of the major risk factors for indoor air pollution-related deaths. Accurately identifying sources exceeding permissible limits and mapping the spatial distribution of indoor formaldehyde are key approaches to mitigating indoor air pollution. However, existing technologies struggle to achieve rapid and precise quantification and source tracing due to limited detection capability and interference from complex environments with multiple coexisting sources. This study developed a highly sensitive formaldehyde tracing system. Through a source-tracing-guided efficient detection approach, the system integrated high-precision optical sensing technology with an innovative dynamic class-based localization algorithm. This successfully resolved the challenge of ambiguous multi-source localization in complex environments, achieving an accuracy rate exceeding 85% with positioning precision better than 0.2 m. During field deployment, the system revealed that formaldehyde removal test kits may cause localized concentration spikes and precisely pinpointed a new wooden bookshelf as the primary emission source. This research provides a closed-loop solution for indoor formaldehyde “detection-tracing-treatment”, offering technical support for establishing healthy building standards and opening new avenues for precise prevention and control of global indoor air safety.

Förderung

  • Hefei Institutes of Physical Science, Chinese Academy of Sciences
  • National Natural Science Foundation of China

Zitieren

APA

Wang, Z., Xing, C., Yang, Y., Ma, W., Sun, Z., Xie, H., Wang, H., & Liu, C. (2026). Integrated Optical Sensing and Source-Tracing Model Resolves Formaldehyde Exposure: Precisely Identifying Multiple Coexisting Carcinogenic Sources Indoors. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c01846

Vancouver

Wang Z, Xing C, Yang Y, Ma W, Sun Z, Xie H, et al. Integrated Optical Sensing and Source-Tracing Model Resolves Formaldehyde Exposure: Precisely Identifying Multiple Coexisting Carcinogenic Sources Indoors. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c01846

BibTeX
@article{Wang2026,
  author = {Wang, Zaiwei and Xing, Chengzhi and Yang, Yue and Ma, Wanchao and Sun, Zhongmou and Xie, Huawei and Wang, Hongfei and Liu, Cheng},
  title = {Integrated Optical Sensing and Source-Tracing Model Resolves Formaldehyde Exposure: Precisely Identifying Multiple Coexisting Carcinogenic Sources Indoors},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c01846}
}
Kostenlos starten →