Tuning Library Length Revealing High Affinity Melamine Aptamers with Opposite Fluorescence Responses for Highly Selective Detection
Analytical Chemistry · 23.06.2026 · 98 (24) · 18031-18041
DOI: 10.1021/acs.analchem.6c01553 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 09.06.2026. Verfasst von Stefen Stangherlin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L3G1, Canada. Hauptthemen laut MEDLINE: Triazines, Aptamers, Nucleotide, SELEX Aptamer Technique, Gene Library. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Government of Canada, University of Waterloo, Canada Research Chairs.
Abstract (Originalsprache)
The adulteration of dairy products with melamine has created an urgent need for reliable, sensitive, and convenient detection methods. Since melamine can form extensive hydrogen bonding and stacking interactions with DNA bases, aptamers represent an attractive platform for melamine sensing. In this work, capture-SELEX was employed using two DNA libraries containing either 30 or 36 randomized nucleotides. The longer library generated a greater diversity of sequence families, including a dominant family featuring more than 30 conserved nucleotides, a structural motif unattainable with the shorter library. Comparison was made with previous length-dependent SELEX experiments. The highest affinity aptamers exhibited a dissociation constant (Kd) of ∼60 nM, as determined by isothermal titration calorimetry. Screening aptamer responses using a thioflavin T fluorescence assay revealed a pair of aptamers with opposite signal readouts, enabling melamine detection with limits of detection of 61 nM and 208 nM, respectively. In 5% (v/v) milk samples, limits of detection of 89 and 315 nM were achieved, respectively. Overall, this study advances understanding of the impact of library length on aptamer selection and provides a set of high affinity aptamers along with a robust, label-free strategy for melamine detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L3G1, Canada.
ORCID-Profile: Juewen Liu
Förderung
- Government of Canada
- University of Waterloo
- Canada Research Chairs
- Natural Sciences and Engineering Research Council of Canada
- Government of Ontario
- Global Water Futures Observatories facility
Zitieren
APA
Stangherlin, S., Wang, S., Fidella, C., Kim, K., & Liu, J. (2026). Tuning Library Length Revealing High Affinity Melamine Aptamers with Opposite Fluorescence Responses for Highly Selective Detection. Analytical Chemistry, 98(24), 18031-18041. https://doi.org/10.1021/acs.analchem.6c01553
Vancouver
Stangherlin S, Wang S, Fidella C, Kim K, Liu J. Tuning Library Length Revealing High Affinity Melamine Aptamers with Opposite Fluorescence Responses for Highly Selective Detection. Analytical Chemistry. 2026;98(24):18031-18041. doi:10.1021/acs.analchem.6c01553
BibTeX
@article{Stangherlin2026,
author = {Stangherlin, Stefen and Wang, Sihan and Fidella, Celine and Kim, Kate and Liu, Juewen},
title = {Tuning Library Length Revealing High Affinity Melamine Aptamers with Opposite Fluorescence Responses for Highly Selective Detection},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {24},
pages = {18031--18041},
doi = {10.1021/acs.analchem.6c01553}
}
EUVIMED