EUVIMEDEUVIMED entdecken
Crossref

Position-Specific Hydrogen Isotope Analysis of Palmitic Acid by GC-Orbitrap Mass Spectrometry

Kesi Yang iD, Longchen Zhu iD, Yihang Hong, Yongbo Peng iD, Hao Xie iD

Analytical Chemistry · 07.07.2026 · 98 (26) · 19663-19674

DOI: 10.1021/acs.analchem.6c01516 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 23.06.2026. Verfasst von Kesi Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: International Center for Isotope Effects Research (ICIER), State Key Laboratory of Critical Earth Material Cycling and Mineral Deposits, Nanjing Univ…. Hauptthemen laut MEDLINE: Palmitic Acid, Gas Chromatography-Mass Spectrometry, Deuterium, Hydrogen. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, Science and Technology Project of China National Petroleum Corporation, National Natural Science Foundation of China (NSFC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The hydrogen isotope composition (δ 2 H) of fatty acids is a promising proxy for tracing cellular metabolic pathways and rates and for cancer diagnosis. However, conventional methods based on gas chromatography-isotope ratio mass spectrometry (GC-IRMS) could only measure molecular-average isotopic values, obscuring position-specific variations that could be more sensitive to metabolisms. To perform position-specific hydrogen isotope analysis (PSIA) of fatty acids, we used a GC-Orbitrap (Exploris 240 GC) to acquire isotopologue ratios of two fragment ions, 12 C 4 2 H 1 H 6 16 O 2 + / 12 C 4 1 H 7 16 O 2 + and 12 C 5 2 H 1 H 8 16 O 2 + / 12 C 5 1 H 9 16 O 2 +, in methyl esters of palmitic acids. To allow longer acquisition of isotopologue ratios of each sample analysis, we added a custom peak-broadening system composed of two four-port switch-valves and a passivated sample loop. This peak broadener is installed between the chromatographic column and the MS transfer line and enables precise capture and release control of target compounds, allowing 12 min stable release of the eluate. Each analysis consumes only 7.6 nmol of sample and reaches experimental precision of 5.4‰ for C 4 H 7 O 2 + and 8.8‰ for C 5 H 9 O 2 + (1 standard deviation of 5 analyses). Using palmitic acid labeled with one 2 H atom in the 12th position, we found negligible hydrogen scrambling. Also, label-addition experiments allow us to compare whole-molecule δ 2 H measurements using GC-IRMS with those from GC-Orbitrap, and we obtained a near-precise match with a correlation slope of 1.044 across a composition range of −223–418‰. We establish a method for position-specific δ 2 H measurement of fatty acids on nanomolar sample quantities, opening possibilities for new geological, environmental, and medical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Palmitic AcidGas Chromatography-Mass SpectrometryDeuteriumHydrogen

Substanzen

Palmitic AcidDeuteriumHydrogen

Autor:innen und Institutionen

  • International Center for Isotope Effects Research (ICIER), State Key Laboratory of Critical Earth Material Cycling and Mineral Deposits, Nanjing University, Nanjing 210023, China.
  • Frontiers Science Center for Critical Earth Material Cycling, School of Earth Sciences and Engineering, Nanjing University, Nanjing 210023, China.

ORCID-Profile: Kesi Yang, Longchen Zhu, Yongbo Peng, Hao Xie

Förderung

  • Fundamental Research Funds for the Central Universities
  • Science and Technology Project of China National Petroleum Corporation
  • National Natural Science Foundation of China (NSFC)
  • New Cornerstone Science Foundation through the XPLORER PRIZE (to Y.P.)

Zitieren

APA

Yang, K., Zhu, L., Hong, Y., Peng, Y., & Xie, H. (2026). Position-Specific Hydrogen Isotope Analysis of Palmitic Acid by GC-Orbitrap Mass Spectrometry. Analytical Chemistry, 98(26), 19663-19674. https://doi.org/10.1021/acs.analchem.6c01516

Vancouver

Yang K, Zhu L, Hong Y, Peng Y, Xie H. Position-Specific Hydrogen Isotope Analysis of Palmitic Acid by GC-Orbitrap Mass Spectrometry. Analytical Chemistry. 2026;98(26):19663-19674. doi:10.1021/acs.analchem.6c01516

BibTeX
@article{Yang2026,
  author = {Yang, Kesi and Zhu, Longchen and Hong, Yihang and Peng, Yongbo and Xie, Hao},
  title = {Position-Specific Hydrogen Isotope Analysis of Palmitic Acid by GC-Orbitrap Mass Spectrometry},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {26},
  pages = {19663--19674},
  doi = {10.1021/acs.analchem.6c01516}
}
Kostenlos starten →