Evaluation of Intracellular Motion in Living Cardiomyocytes by a Multi-Microsphere 3D Sensing System
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.6c01168 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Si Tang und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang110016, China. Hauptthemen laut MEDLINE: Myocytes, Cardiac, Microspheres, Imaging, Three-Dimensional. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Liaoning Province Natural Science Fund Plan Doctoral Research Startup Project, National Natural Science Foundation of China (NSFC), the New Cornerstone Science Foundation through the XPLORER PRIZE.
Abstract (Originalsprache)
Precise quantification of cardiomyocyte mechanical motion has substantially advanced the cardiac physiology research. Dysregulated rhythmic contractions in cardiomyocytes are predominantly driven by intracellular structural perturbations. However, high-resolution three-dimensional (3D) mapping of intracellular motion within cardiomyocytes remains a technical challenge. We herein developed an innovative intracellular 3D motion-sensing system integrated with a stable motion-tracking algorithm to quantify intracellular contraction trajectories. Using this system, we observed that the propagation velocity of the intracellular motion decreases from the cardiomyocyte center to the periphery. These velocity changes correlate with constraints imposed by the cell membrane and cytoskeleton, enabling our method to detect subtle cellular alterations. To validate this system, we induced cytoskeletal depolymerization with cytochalasin D, resulting in a marked reduction in the cellular motion velocity. Collectively, these findings demonstrate that our intracellular motion sensing system offers a novel platform for in vitro single-cell multiposition motility assessment, toxicity screening, and disease-associated phenotype detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang110016, China.
- College of Light Industry, Liaoning University, Shenyang110036, China.
- Department of General Surgery, Shengjing Hospital of China Medical University, Shenyang110004, China.
ORCID-Profile: Huiyao Shi
Förderung
- Liaoning Province Natural Science Fund Plan Doctoral Research Startup Project
- National Natural Science Foundation of China (NSFC)
- the New Cornerstone Science Foundation through the XPLORER PRIZE
Zitieren
APA
Tang, S., Shi, H., Su, C. Q., Zhao, Y., & Liu, L. (2026). Evaluation of Intracellular Motion in Living Cardiomyocytes by a Multi-Microsphere 3D Sensing System. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c01168
Vancouver
Tang S, Shi H, Su CQ, Zhao Y, Liu L. Evaluation of Intracellular Motion in Living Cardiomyocytes by a Multi-Microsphere 3D Sensing System. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c01168
BibTeX
@article{Tang2026,
author = {Tang, Si and Shi, Huiyao and Su, Chanmin Quanmin and Zhao, Ying and Liu, Lianqing},
title = {Evaluation of Intracellular Motion in Living Cardiomyocytes by a Multi-Microsphere 3D Sensing System},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c01168}
}
EUVIMED