EUVIMEDEUVIMED entdecken
Crossref

Fluorescent Bubble Sensor Array and a Conceptual Platform for High-Performance Sensing of Gaseous Nerve Agent Simulants

Wendan Luo, Yijia Chen, Jinghua Yu, Chun Yang, Zhiyan Huang iD, Taihong Liu iD, Liping Ding iD, Yu Fang iD

Analytical Chemistry · 28.04.2026 · 98 (16) · 12112-12121

DOI: 10.1021/acs.analchem.6c00915 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 15.04.2026. Verfasst von Wendan Luo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Applied Surface and Colloid Chemistry of Ministry of Education, Shaanxi Provincial Key Laboratory of New Concept Sensors and Molecu…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Shaanxi Provincial Science Fund for Distinguished Young Scholars, Key Laboratory of Drugs Analysis and Intelligent-Monitoring of National Narcotics Laboratory Shaanxi Regional Center.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bubble optical sensors and droplet microreactors, featuring the intrinsic advantages of high mass transfer and efficient utilization of active substances, have recently attracted extensive attention. Herein, two reactive fluorophores (OBP and PIDT) were initially evaluated for detecting the nerve agent simulant, and related sensing mechanisms were manifested comprehensively. Thereafter, two fluorescent bubbles were optimized based on the two doping active fluorophores, possessing long durability over 100 min and fast turn-on response to gaseous analytes. In contrast to the homogeneous detection in droplets, a dramatic 24.9-fold signal amplification capability was observed in the optimized bubble sensors. The term of a high surface area-to-volume ratio, unidirectional gas absorption, and spontaneous analyte enrichment is rationalized principally. Furthermore, a conceptual sensing platform was fabricated for detecting gaseous diethylchlorophosphate (DCP), a nerve agent simulant. Consumption of the stock solution for each detection was minimized to 2.0 μL, with a favorable low detection value of 1.32 ppt for gaseous DCP. Importantly, a binary-component bubble sensor array was composed virtually, and some potential acid interferences like HCl were discriminated based on the acquired multiplexed signals. The present work displays the first fluorescent bubble sensor array for high-performance gaseous detection and a conceptual sensing platform, paving the way for advanced sensing applications.

Autor:innen und Institutionen

  • Key Laboratory of Applied Surface and Colloid Chemistry of Ministry of Education, Shaanxi Provincial Key Laboratory of New Concept Sensors and Molecular Materials, School of Chemistry and Chemical Engineering, Shaanxi N…
  • National Anti-Drug Laboratory Shaanxi Regional Center (Anti-Drug Technology Center of Shaanxi Provincial Public Security Department), Xi'an 710115, P. R. China.
  • Key Laboratory of Applied Surface and Colloid Chemistry of Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, P. R. China.

ORCID-Profile: Zhiyan Huang, Taihong Liu, Liping Ding, Yu Fang

Förderung

  • National Key Research and Development Program of China
  • Shaanxi Provincial Science Fund for Distinguished Young Scholars
  • Key Laboratory of Drugs Analysis and Intelligent-Monitoring of National Narcotics Laboratory Shaanxi Regional Center
  • Key Laboratory of Drug Monitoring and Control of Ministry of Public Security

Zitieren

APA

Luo, W., Chen, Y., Yu, J., Yang, C., Huang, Z., Liu, T., Ding, L., & Fang, Y. (2026). Fluorescent Bubble Sensor Array and a Conceptual Platform for High-Performance Sensing of Gaseous Nerve Agent Simulants. Analytical Chemistry, 98(16), 12112-12121. https://doi.org/10.1021/acs.analchem.6c00915

Vancouver

Luo W, Chen Y, Yu J, Yang C, Huang Z, Liu T, et al. Fluorescent Bubble Sensor Array and a Conceptual Platform for High-Performance Sensing of Gaseous Nerve Agent Simulants. Analytical Chemistry. 2026;98(16):12112-12121. doi:10.1021/acs.analchem.6c00915

BibTeX
@article{Luo2026,
  author = {Luo, Wendan and Chen, Yijia and Yu, Jinghua and Yang, Chun and Huang, Zhiyan and Liu, Taihong and Ding, Liping and Fang, Yu},
  title = {Fluorescent Bubble Sensor Array and a Conceptual Platform for High-Performance Sensing of Gaseous Nerve Agent Simulants},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {16},
  pages = {12112--12121},
  doi = {10.1021/acs.analchem.6c00915}
}
Kostenlos starten →