Native Charge Detection Mass Spectrometry of Kilobase-Scale Messenger RNAs
Analytical Chemistry · 09.06.2026 · 98 (22) · 16152-16162
DOI: 10.1021/acs.analchem.6c00192 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 22.05.2026. Verfasst von Raihana Afroz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States. Hauptthemen laut MEDLINE: RNA, Messenger, Mass Spectrometry. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Graduate School, University of Minnesota, American Society for Mass Spectrometry, University of Minnesota.
Abstract (Originalsprache)
Charge detection mass spectrometry (CDMS) enables direct measurement of mass and charge for individual ions and overcomes fundamental limitations of conventional electrospray mass spectrometry for large, heterogeneous biomolecules. Messenger RNAs (mRNAs) represent a particularly challenging analytical target, as transcripts often span thousands of nucleotides, exhibit substantial heterogeneity, and form higher-order oligomers that are difficult to assess using existing workflows. Here, we optimize and evaluate native CDMS for intact analysis of long mRNAs and conduct systematic comparison of positive and negative analysis polarities. Using a panel of commercially available mRNAs ranging from approximately 1,000 to 4,500 nucleotides, we demonstrate that native CDMS enables direct and accurate mass measurement of intact mRNAs while detecting process-related impurities (truncations, dimers, etc.). Collisional activation improves mass accuracy by reducing adduct heterogeneity while preserving the ability to resolve impurity populations. Across all constructs, CDMS provides access to charge distributions that scale with transcript length and respond predictably to activation, denaturation, and polarity, offering insight into ion charging behavior and charge accommodation for large RNAs. Negative polarity measurements generally access higher charge states than positive polarity, particularly for the largest transcripts, improving sensitivity and relative size discrimination, while intact mass accuracy remains comparable between polarities when appropriate experimental strategies are employed. Together, these results establish native CDMS as a versatile and information-rich platform for intact mRNA characterization, providing simultaneous access to mass, charge, and impurity information that complements existing analytical methods and supports emerging needs in RNA biotherapeutic development.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States.
- Thermo Fisher Scientific, San Jose, California 95134, United States.
ORCID-Profile: Kyle P Bowen, Weijing Liu, Varun V Gadkari
Förderung
- Graduate School, University of Minnesota
- American Society for Mass Spectrometry
- University of Minnesota
Zitieren
APA
Afroz, R., Bowen, K. P., Liu, W., & Gadkari, V. V. (2026). Native Charge Detection Mass Spectrometry of Kilobase-Scale Messenger RNAs. Analytical Chemistry, 98(22), 16152-16162. https://doi.org/10.1021/acs.analchem.6c00192
Vancouver
Afroz R, Bowen KP, Liu W, Gadkari VV. Native Charge Detection Mass Spectrometry of Kilobase-Scale Messenger RNAs. Analytical Chemistry. 2026;98(22):16152-16162. doi:10.1021/acs.analchem.6c00192
BibTeX
@article{Afroz2026,
author = {Afroz, Raihana and Bowen, Kyle P and Liu, Weijing and Gadkari, Varun V},
title = {Native Charge Detection Mass Spectrometry of Kilobase-Scale Messenger RNAs},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {22},
pages = {16152--16162},
doi = {10.1021/acs.analchem.6c00192}
}
EUVIMED