EUVIMEDEUVIMED entdecken
Crossref

A Prolonged Multimodal Lateral Flow Immunoassay Enabled by Synergistic Peroxidase–Heme Nanohybrids

Zixuan Ren, Jun Chen, Yue Cui iD

Analytical Chemistry · 11.08.2026 · 98 (31) · 22674-22686

DOI: 10.1021/acs.analchem.6c00014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 28.07.2026. Verfasst von Zixuan Ren und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing100871, P. R. Chi…. Hauptthemen laut MEDLINE: Heme, Troponin I. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Science and Technology Planning Project, National Key R&D Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Horseradish peroxidase (HRP)-catalyzed lateral flow immunoassays (LFIAs) are powerful platforms for sensitive biosensing. However, the limited stability and short-lived catalytic activity of HRP significantly constrain their broader applications. Conventional HRP-based chemiluminescence (CL)-LFIAs typically emit for about 1 min before rapid decay, restricting signal capture. Herein, we report for the first time a prolonged CL/colorimetric LFIA enabled by β-cyclodextrin (β-CD)-functionalized polydopamine (PDA) nanospheres coloaded with HRP and heme, denoted β-CD-PDA/Heme/HRP (CPHH). This hybrid architecture integrates the complementary properties of both catalytic components: heme provides long-lasting but moderate CL, while HRP contributes strong yet transient luminescence. This synergistic interplay yields clearly enhanced and sustained signal output lasting up to 5 min on paper-based substrates, allowing sensitive and stable detection of cardiac troponin I (cTnI). When applied in an LFIA device, the CPHH probe can offer three readout modes, colorimetric (CM), enhanced colorimetric (ECM), and chemiluminescent (CL), covering a wide detection range of 0.1–500 ng/mL with limit of detection values of 10 ng/mL (CM), 0.47 ng/mL (ECM), and 0.95 ng/mL (CL). Further clinical research confirms its robustness and accuracy in real human samples. This work provides a new design paradigm for durable chemiluminescent nanoprobes and multifunctional LFIA systems for rapid and reliable cTnI detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemeTroponin IImmunoassayHorseradish PeroxidaseHumansbeta-CyclodextrinsPolymersIndolesLuminescent MeasurementsColorimetryNanospheres

Substanzen

Horseradish Peroxidasebeta-CyclodextrinsHemePolymerspolydopamineTroponin IIndolesbetadex

Autor:innen und Institutionen

  • School of Materials Science and Engineering, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing100871, P. R. China.

ORCID-Profile: Yue Cui

Förderung

  • National Natural Science Foundation of China
  • Beijing Science and Technology Planning Project
  • National Key R&D Program of China
  • State Key Laboratory of Vascular Homeostasis and Remodeling of Peking University

Zitieren

APA

Ren, Z., Chen, J., & Cui, Y. (2026). A Prolonged Multimodal Lateral Flow Immunoassay Enabled by Synergistic Peroxidase–Heme Nanohybrids. Analytical Chemistry, 98(31), 22674-22686. https://doi.org/10.1021/acs.analchem.6c00014

Vancouver

Ren Z, Chen J, Cui Y. A Prolonged Multimodal Lateral Flow Immunoassay Enabled by Synergistic Peroxidase–Heme Nanohybrids. Analytical Chemistry. 2026;98(31):22674-22686. doi:10.1021/acs.analchem.6c00014

BibTeX
@article{Ren2026,
  author = {Ren, Zixuan and Chen, Jun and Cui, Yue},
  title = {A Prolonged Multimodal Lateral Flow Immunoassay Enabled by Synergistic Peroxidase–Heme Nanohybrids},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {31},
  pages = {22674--22686},
  doi = {10.1021/acs.analchem.6c00014}
}
Kostenlos starten →