Intrinsic crRNA Scaffold Dynamic Reassembly Powered Cas12a Cascade Amplification for Multiplexed Detection
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.5c07867 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Cheng Jun Zha und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, Key Laboratory for Green Organic Synthesis and Applica…. Hauptthemen laut MEDLINE: Biosensing Techniques, CRISPR-Associated Proteins, RNA, Endodeoxyribonucleases. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Natural Science Foundation of Hunan Province, National Natural Science Foundation of China, Xiangtan University.
Abstract (Originalsprache)
The reassembly of the intrinsic crRNA scaffold with complementary ssDNA activates Cas12a trans-cleavage activity, thereby overcoming the limitations of conventional split crRNA engineering strategies and resulting in expanded target detection range, reduced background interference, and improved signal-to-noise ratio. Here, we have developed a novel scaffold RNA reassembly biosensor that ingeniously couples catalytic nucleic acid (ribozyme or DNAzyme) cleavage as a signal transduction element with the Cas12a cascade amplification, enabling highly sensitive detection of diverse targets including miRNAs, small molecules, and metal ions. The system employs an intrinsic amplifier that integrates signal output with crRNA regeneration. Each Cas12a cleavage event not only generates a fluorescent signal but also releases scaffold RNA, which promptly reassembles into functional crRNA complexes, thereby driving continuous Cas12a activation. This crRNA scaffold dynamic reassembly circuit enables cascade signal amplification without requiring additional crRNA or activators, thereby facilitating one-pot detection with shortened reaction time, while simultaneously enhancing detection sensitivity and minimizing aerosol contamination risks. Experimental results demonstrated excellent sensitivity, specificity, and robustness in complex matrices such as serum and environmental water samples. Moreover, the system achieved accurate miRNA detection in different cell lines and clinical samples, which was corroborated by lateral flow analysis and showed strong agreement with the RT-qPCR gold-standard method. Owing to its modular design and powerful amplification capacity, this platform holds broad potential for versatile biosensing applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, Key Laboratory for Green Organic Synthesis and Application of Hunan Province, College of Chemistry, Xiangtan University, Xia…
- Hunan Provincial Clinical Research Center for Metabolic Associated Fatty Liver Disease, Clinical Research Institute, the Affiliated Nanhua Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan 42…
ORCID-Profile: Zhan Ming Ying
Förderung
- Natural Science Foundation of Hunan Province
- National Natural Science Foundation of China
- Xiangtan University
Zitieren
APA
Zha, C. J., Zhang, H. S., Su, M., Nie, Y. G., & Ying, Z. M. (2026). Intrinsic crRNA Scaffold Dynamic Reassembly Powered Cas12a Cascade Amplification for Multiplexed Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c07867
Vancouver
Zha CJ, Zhang HS, Su M, Nie YG, Ying ZM. Intrinsic crRNA Scaffold Dynamic Reassembly Powered Cas12a Cascade Amplification for Multiplexed Detection. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c07867
BibTeX
@article{Zha2026,
author = {Zha, Cheng Jun and Zhang, Hong-Shuai and Su, Mei and Nie, Yin Gang and Ying, Zhan Ming},
title = {Intrinsic crRNA Scaffold Dynamic Reassembly Powered Cas12a Cascade Amplification for Multiplexed Detection},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.5c07867}
}
EUVIMED