Culture-Free Microfluidics for Ultra-Rapid Antimicrobial Susceptibility Testing with AI in Resource-Limited Settings

Chao Wan, Huijuan Yuan, Chenxi Dai, Dongjuan Chen, Xudong Zhao, Xin Ma, Xiang Liu, Yuxiao Shu, Shunji Li, Zeyu Miao, Xin Wang, Wei Du und 4 weitere

Analytical Chemistry · 24.03.2026 · 98 (11) · 8349-8366

DOI: 10.1021/acs.analchem.5c07535 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 11.03.2026. Verfasst von Chao Wan und 15 weiteren Autor:innen. Beteiligte Einrichtung: The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Labo…. Hauptthemen laut MEDLINE: Anti-Bacterial Agents, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Basic and Applied Basic Research Foundation of Guangdong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The misuse of antibiotics has accelerated the rise of antimicrobial resistance (AMR), particularly in resource-limited regions, posing a critical threat to global public health. Current antibiotic susceptibility test (AST) technologies are trapped in a paradox: regions most in need of rapid diagnostics face the greatest implementation barriers due to culture-based delays and infrastructure dependence. No existing platform simultaneously overcomes these spatiotemporal constraints while maintaining phenotypic reliability. Combining the self-healing property of skins with discrete state control of D flip-flop, we present a low-cost ($0.62) centrifugal microfluidic chip with self-healing valves (μCFC-shv) that integrates bacterial enrichment (1000-fold without time-consuming incubation), antibiotic gradient generation, and AST. The shvs autonomously actuate/reseal with centrifugal speed changes, enabling robust, long-term, and repeatable use. The μCFC-shv detects pathogens within 5 min postenrichment, achieving 100% sensitivity and specificity, with a 10 °CFU/mL detection limit. Critically, it performs culture-free AST in 30 min of antibiotic exposure, demonstrating an accuracy of 97.39% across 306 clinical cases, comparable or superior to current single-bacterium detection methods. To overcome ambient light interference and subjective interpretation, we integrate a machine learning model that automates result analysis with 98.83% accuracy. This combination of accessibility and culture-free strategy makes μCFC-shv a transformative tool for AST, especially in resource-limited areas, advancing global efforts to combat bacterial infections and AMR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anti-Bacterial AgentsMicrofluidic Analytical TechniquesLab-On-A-Chip DevicesMicrobial Sensitivity TestsResource-Limited SettingsRapid Diagnostic TestsIntelligent Systems

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, C…
  • Department of Laboratory Medicine, Children's Infectious Diseases Prevention and Control Center, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technolog…
  • Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
  • Department of Laboratory Medicine, Wuhan Children's Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430016, China.
  • Shenzhen Huazhong University of Science and Technology Research Institute, Shenzhen 518000, China.

ORCID-Profile: Yiwei Li, Peng Chen, Bi-Feng Liu

Förderung

  • National Key Research and Development Program of China
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Natural Science Foundation of China
  • Hubei Provincial World-Class Universities and First-Class Disciplines Construction Fund for Central Universities

Zitieren

APA

Wan, C., Yuan, H., Dai, C., Chen, D., Zhao, X., Ma, X., Liu, X., Shu, Y., Li, S., Miao, Z., Wang, X., Du, W., Feng, X., Li, Y., Chen, P., & Liu, B. F. (2026). Culture-Free Microfluidics for Ultra-Rapid Antimicrobial Susceptibility Testing with AI in Resource-Limited Settings. Analytical Chemistry, 98(11), 8349-8366. https://doi.org/10.1021/acs.analchem.5c07535

Vancouver

Wan C, Yuan H, Dai C, Chen D, Zhao X, Ma X, et al. Culture-Free Microfluidics for Ultra-Rapid Antimicrobial Susceptibility Testing with AI in Resource-Limited Settings. Analytical Chemistry. 2026;98(11):8349-8366. doi:10.1021/acs.analchem.5c07535

BibTeX
@article{Wan2026,
  author = {Wan, Chao and Yuan, Huijuan and Dai, Chenxi and Chen, Dongjuan and Zhao, Xudong and Ma, Xin and Liu, Xiang and Shu, Yuxiao and Li, Shunji and Miao, Zeyu and Wang, Xin and Du, Wei and Feng, Xiaojun and Li, Yiwei and Chen, Peng and Liu, Bi-Feng},
  title = {Culture-Free Microfluidics for Ultra-Rapid Antimicrobial Susceptibility Testing with AI in Resource-Limited Settings},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {11},
  pages = {8349--8366},
  doi = {10.1021/acs.analchem.5c07535}
}
Kostenlos starten →