From Hapten Design to Mechanism Exploration: Developing a High-Specificity Immunochromatography Strip for Fluridone Detection
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.5c07383 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Qingqing Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jian…. Hauptthemen laut MEDLINE: Haptens, Chromatography, Affinity, Pyridones, Herbicides. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: State Key Laboratory of Food Science and Resources, Jiangsu Provincial Department of Science and Technology, National Natural Science Foundation of China.
Abstract (Originalsprache)
Fluridone (FLU), a commonly used aquatic herbicide in water environmental management, poses threats to aquatic ecosystems and aquatic product safety due to issues of misuse, abuse, and residues. Therefore, it is necessary to develop highly sensitive detection methods. Here, two novel FLU haptens with distinct spacer arms were rationally designed, and the best scheme was selected through computer-aided chemical simulations. Through mouse immunization and cell fusion techniques, a high-affinity, specific antibody against FLU (mAb-2B2) was obtained. The affinity constant (Ka) and maximal half-inhibitory concentration (IC50) of mAb-2B2 were 3.72 × 109 L/mol and 0.50 ng/mL, respectively, with negligible cross-reactivity to six other analogues. Molecular docking analysis revealed that the key amino acid residues mediating the specific recognition of mAb-2B2 were primarily ARG 99 (at distances of 2.47, 3.88, and 2.80 Å), ARG 96 (at 3.56 Å), ARG 100 (at 5.32 Å), and TYR 91 (at 3.79 Å). Based on mAb-2B2, a gold nanoparticles-immunochromatographic strips (GNPs-ICS) method for detecting FLU residues in river water, crayfish, and fish samples was established for the first time, with detection ranges of 4.22-31.55 ng/mL, 13.61-65.01 μg/kg, and 5.51-35.40 μg/kg, respectively. This method was demonstrated to be suitable for rapid primary screening of FLU residues in environmental and aquatic products.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, China.
ORCID-Profile: Xinxin Xu, Xiaoling Wu, Liguang Xu, Chuanlai Xu, Hua Kuang, Maozhong Sun
Förderung
- State Key Laboratory of Food Science and Resources
- Jiangsu Provincial Department of Science and Technology
- National Natural Science Foundation of China
Zitieren
APA
Liu, Q., Guo, L., Liu, L., Xu, X., Wu, X., Xu, L., Xu, C., Kuang, H., & Sun, M. (2026). From Hapten Design to Mechanism Exploration: Developing a High-Specificity Immunochromatography Strip for Fluridone Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c07383
Vancouver
Liu Q, Guo L, Liu L, Xu X, Wu X, Xu L, et al. From Hapten Design to Mechanism Exploration: Developing a High-Specificity Immunochromatography Strip for Fluridone Detection. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c07383
BibTeX
@article{Liu2026,
author = {Liu, Qingqing and Guo, Lingling and Liu, Liqiang and Xu, Xinxin and Wu, Xiaoling and Xu, Liguang and Xu, Chuanlai and Kuang, Hua and Sun, Maozhong},
title = {From Hapten Design to Mechanism Exploration: Developing a High-Specificity Immunochromatography Strip for Fluridone Detection},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.5c07383}
}
EUVIMED